34
ADJUSTMENTS &
REPLACEMENT OF
COMPONENTS
Gas Valve Removal
1. Shut off gas supply to the heater. Remove gas pip-
ing to gas valve inlet.
2. Disconnect wires, pilot tubing and bleed line, if
required.
3. Turn vertical gas pipe from manifold slightly and
unscrew gas valve.
4. Reverse above procedure to re-install.
Pilot Removal and Cleaning
1. Disconnect pilot tubing at pilot and sensor/igniter
wire. Remove screws holding pilot bracket to burn-
er drawer.
2. Remove pilot and bracket, clean pilot of debris,
small bugs, etc., with wire or small brush.
3. Replace pilot, pilot tubing, sensor ignition wires
and check for leaks.
Burner Drawer Removal
1. Shut off power and gas supply to the heater.
Disconnect union(s) and pilot tubing, then loosen
and remove burner hold down screws.
2. Disconnect wires at gas valve and slide burner
drawer out.
Main Burner and Orifice Removal
1. Remove screws and burner hold down bracket.
2. Lift burners from slotted spacer and slide from ori-
fices. Clean with a wire brush.
3. Orifices usually do not need to be replaced. To
clean, run either copper wire or wood through ori-
fice. Do not enlarge hole. To remove orifice, use a
socket wrench and remove the manifold. DO NOT
over tighten when reinstalling.
High Limit or Tankstat Removal
1. Turn off electrical power.
2. Remove front inspection panel.
3. Remove wires to high limit and loosen screws
holding high limit to cabinet.
4. Remove wedge clip holding sensing bulb in con-
trol well.
5. Remove high limit and install a new one.
6. Check control operation before leaving job.
Flame Roll-Out Switch Replacement
1. Shut off electrical power to the heater.
2. Remove wiring connections to switch.
3. Remove screws (2) holding the switch.
4. Reverse above procedure to re-install.
Vent Thermal Switch Replacement
1. Shut off electrical power to the heater.
2. Remove wiring connections to switch.
3. Remove the screws (2).
4. Reverse above procedure to re-install.
Ignition Module Replacement
1. Shut off electrical power to the heater.
2. Remove control cover screws and open control
compartment.
3. Disconnect wiring connections to module.
4. Remove screws (2) holding module.
5. Reverse above procedure to re-install.
Transformer Replacement
1. Shut off electrical power to the heater.
2. Remove control cover screws and open control
compartment.
3. Disconnect wiring connections from transformer
leads.
4. Remove screws (2) holding transformer.
5. Reverse above procedure to re-install.
CAUTION:
Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
DANGER: SHOCK HAZARD:
Make sure electri-
cal power to the heater is disconnected to avoid
potential serious injury or damage to components.
NOTE:
If the heat exchanger is sooted badly, the
burner hold down bracket and spacer can become
distorted from direct flame impingement and this
usually necessitates replacement of these parts.
Summary of Contents for 2600401
Page 17: ...17 Wiring Diagrams Fig 15 Standing Pilot Model 0260 FIELD INSTALLED...
Page 18: ...18 Fig 16 Intermittent Ignition Device IID Model 0260...
Page 19: ...19 Fig 17 Intermittent Ignition Device IID Models 0330 0400...
Page 20: ...20 Fig 18 Intermittent Ignition Device IID Model 0261 Low NOx...
Page 21: ...21 Fig 19 Intermittent Ignition Device IID Models 0331 0401 Low NOx...
Page 37: ...37...
Page 38: ...38...
Page 39: ...39...