background image

36

DIAGNOSTIC CODE

SYMPTOM

SOLUTION

Up Arrow Flash(es)

Down Arrow

Flash(es)

4

1-4

Door is moving stops and or reverses.

Manually open and close the door. Check for binding or obstructions, such as a broken spring or door
lock, correct as needed. If the door is binding or sticking contact a trained door systems technician. If door
is not binding or sticking attempt to reprogram travel (refer to page 25).

4

5

Opener runs approximately 6-8", stops and reverses.

Communication error to travel module. Check travel module connections, replace module if necessary.

4

6

The garage door opener will not close and the light bulbs
flash.

Safety sensors are misaligned or were momentarily obstructed. Realign both sensors to ensure both
LEDs are steady and not flickering. Make sure nothing is hanging or mounted on the door that would
interrupt the sensor's path while closing.

The garage door opener will NOT enter Wi-Fi

®

LEARN mode:

l

After the initial installation of the garage door opener, the garage door opener must
complete a full cycle (open and closed) before the Wi-Fi LEARN mode can be activated.

l

If there has been a recent power outage, the garage door opener must complete a full cycle
before the Wi-Fi LEARN mode can be activated.

See page 29 to activate Wi-Fi LEARN mode.

The garage door opener will NOT connect to my Wi-Fi network:

l

Network password entered incorrectly. Double check your network password and re-enter.

l

Weak Wi-Fi signal in the garage. Ensure the Wi-Fi signal is reaching the garage, see page
3.

The garage door opener can beep for several reasons:

l

Garage door opener has been activated through a device or feature such as Timer-to-Close,
garage door monitor or MyQ

®

Internet Gateway, see page 28.

My door will not close and the light bulbs blink on my motor unit:

The safety reversing sensor must be connected and aligned correctly before the garage door opener
will move in the down direction.

l

Verify the safety sensors are properly installed, aligned and free of any obstructions.

My remote control will not activate the garage door:

l

Verify the lock feature is not activated on the door control.

l

Reprogram the remote control.

l

If the remote control will still not activate the door check the diagnostic codes to ensure the
garage door opener is working properly.

My garage door opener light(s) will not turn off when the door is open:

The garage door opener is equipped with a feature that turns the light on when the safety reversing
sensors have been obstructed or when the motion sensor on the door control detects movement in the
garage. This feature can be disabled using the door control, see page 31.

My neighbor’s remote control opens my garage door:

Erase the memory from your garage door opener and reprogram the remote control(s).

My vehicle's Homelink

®

is not programming to my garage door opener:

Depending on the make, model, and year of your vehicle an external adapter may be required. Visit
www.homelink.com for additional information.

Troubleshooting

Summary of Contents for U:TRA II 8587WRGD

Page 1: ...CLOSE unless the Protector System is connected and properly aligned Periodic checks of the garage door opener are required to ensure safe operation This garage door opener is ONLY compatible with MyQ...

Page 2: ...ompany them The hazard may come from something mechanical or from electric shock Read the warnings carefully Mechanical Electrical When you see this Signal Word on the following pages itwill alertyou...

Page 3: ...ician ifgarage door binds sticks or is outof balance An unbalanced garage door may NOT reverse when required l NEVER try to loosen move or adjustgarage door door springs cables pulleys brackets or the...

Page 4: ...4 Tools Needed 3 16 5 32 5 16 7 16 1 2 5 8 9 16 1 4 7 16 Preparation...

Page 5: ...white black wire attached Sending senor 1 receiving sensor 1 and safety sensor brackets 2 P Safety labels and literature Q Rail grease R Remote control 893RGX Hardware Assembly Chassis Support Bracket...

Page 6: ...eviously removed washered boltand lock nut 4 Position the chain around the garage door opener sprocket 5 Attach the chain spreader to the garage door opener with screws 6 Guide the chain around the se...

Page 7: ...matching hole in the bracket Complete the connection by inserting the 8 32x3 8 screw through the back flange and the hole in rail support Washerd Bolt 5 16 18x1 2 Screw 8 32x3 8 Hex Bolt 1 4 20x5 8 L...

Page 8: ...ease 7 NEVER connectgarage door opener to power source until instructed to do so 8 NEVER wear watches rings or loose clothing while installing or servicing opener They could be caughtin garage door or...

Page 9: ...he line onto the header wall above the door You can fasten the header bracketwithin 4 feet 1 22 m ofthe leftor rightofthe door center only ifa torsion spring or center bearing plate is in the way or y...

Page 10: ...ten the bracketsecurely to a structural supportwith lag screws Wall Mount Optional Mounting Holes Vertical Centerline of Garage Door Header Wall Header Bracket 2x4 Structural Support Door Spring Garag...

Page 11: ...mage to garage door restgarage door opener rail on 2x4 placed on top section of door 1 Remove the packing material and liftthe garage door opener onto a ladder 2 Fully open the door and place a 2x4 la...

Page 12: ...the motor unitto the structural support 2 Cutboth pieces ofthe hanging bracketto required lengths 3 Drill 3 16 pilotholes in the structural supports 4 Attach one end ofeach bracketto a supportwith 5 1...

Page 13: ...r DEATH from a falling garage door l Ifpossible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could resultin an open door...

Page 14: ...ket2 4 5 10 cm below the top edge ofthe door OR directly below any structural supportacross the top ofthe door 3 Mark drill holes and install as follows depending on your door s construction Metalorli...

Page 15: ...les as far apartas possible and attach using the bolts nuts and lock washers NOTE Ifthe holes do notline up reverse the straightdoor arm Selecttwo aligned holes as far apartas possible and attach usin...

Page 16: ...of5 feet 1 5 m where small children cannotreach and away from the moving parts ofthe door For gang box installations itis notnecessary to drill holes or install the drywall anchors Use the existing ho...

Page 17: ...x or pre wired installations Do notpierce the wire with the staple as this may cause a shortor an open circuit 2 Strip 7 16 inch 11 mm ofinsulation from the end ofthe wire near the garage door opener...

Page 18: ...and the garage door opener lights will flash 10 times NOTE For energy efficiency the garage door opener will enter sleep mode when the door is fully closed The sleep mode shuts the garage door opener...

Page 19: ...r bracket No more than 6 inches 15 cm Carriage Bolt 1 4 20x1 2 Wing Nut 1 4 20 1 2 3 OPTION B WALL INSTALLATION Ifadditional clearance is needed an extension bracket notprovided or wood blocks can be...

Page 20: ...ge Bolt 1 4 20x1 2 Wing Nut 1 4 20 3 4 2 Wire the Safety Reversing Sensors PRE WIRED INSTALLATIONS Ifyour garage already has wires installed for the safety reversing sensors see page 20 HARDWARE Insul...

Page 21: ...te black wire would connectto the purple wire 4 Atthe garage door opener strip 7 16 inch 11 mm ofinsulation from each end ofthe wires previously chosen for the safety reversing sensors Twistthe like c...

Page 22: ...utlet Ifthe plug doesn tfitinto your outlet contacta qualified electrician to install the proper outlet THERE ARE TWO OPTIONS FOR CONNECTING POWER OPTION A TYPICAL WIRING 1 Plug in the garage door ope...

Page 23: ...rectly Green LED Amber LED If the receiving sensor is in direct sunlight switch it with sending sensor so it is on the opposite side of the door invisible light beam SENDING SENSOR RECEIVING SENSOR IF...

Page 24: ...designed with electronic controls to make setup and adjustments easy The adjustments allow you to program where the door will stop in the open UP and close DOWN position The electronic controls sense...

Page 25: ...esired DOWN position NOTE The UP and DOWN Buttons can be used to move the door up and down as needed 5 Once the door is in the desired DOWN position press and release the AdjustmentButton The garage d...

Page 26: ...tactwith the 1 1 2 inch board remove the board and open close the door 3 or 4 times to testthe adjustment Ifthe garage door opener continues to fail the safety reversal test call a trained door system...

Page 27: ...NEVER use handle to pull garage door open or closed Ifrope knotbecomes untied you could fall 9 After ANY adjustments are made the safety reversal system MUST be tested 10 Safety reversal system MUST...

Page 28: ...door opener down until activated The sleep mode is sequenced with the garage door opener lightbulb as the lightbulb turns offthe sensor LEDs will turn offand whenever the garage door opener lights tu...

Page 29: ...on and off You have 20 minutes to complete the connection process beep SETUP WIFI TO REMOTE 2 CONNECT TO THE MyQ Wi Fi NETWORK On your mobile device go to Settings Wi Fi and selectthe network with the...

Page 30: ...ntrol and keyless entry This feature is useful for added peace ofmind when the home is empty i e vacation TIMER TO CLOSE TTC DO NOT enable TTC ifoperating a one piece door TTC is to be used ONLY with...

Page 31: ...your garage door opener lights or a keyless entry SETTINGS Press the navigation button below the down arrow till you see TEMPERATURE to view the Settings menu Display the temperature in Fahrenheit or...

Page 32: ...he garage door opener lights will flash or two clicks will be heard when the code has been programmed Repeatthe steps above for programming additional remote controls or keyless entry devices Ifprogra...

Page 33: ...nt Button To Open the Door Manually To preventpossible SERIOUS INJURY or DEATH from a falling garage door l Ifpossible use emergency release handle to disengage trolley ONLY when garage door is CLOSED...

Page 34: ...ach side with the visor clip Insertreplacement battery positive side up Replace the batteries with only 3V CR2032 coin cell batteries Dispose ofold batteries properly NOTICE To complywith FCC and orIn...

Page 35: ...e misaligned or were momentarily obstructed Realign both sensors to ensure both LEDs are steady and notflickering Make sure nothing is hanging or mounted on the door thatwould interruptthe sensors pat...

Page 36: ...ork password and re enter l Weak Wi Fi signal in the garage Ensure the Wi Fi signal is reaching the garage see page 3 The garage dooropenercan beep forseveralreasons l Garage door opener has been acti...

Page 37: ...2 0 remote control or a MyQ Internet Gateway Plugs into any interior outlet 829LM Garage and Gate Monitor Monitor open closed status for up to 4 MyQ compatible garage door openers or gate operators an...

Page 38: ...ITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE APPLICABLE LIMITED WARRANTY PERIOD SET FORTH ABOVE FOR THE RELATED COMPONENT S AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH P...

Page 39: ...41A3489 6 Trolley Threaded Shaft 109B48 Not Shown Rail Grease 83A11 2 Description Part Number 1 Curved Door Arm 178B35 2 Door Bracket with Clevis Pin and Fastener 41A5047 3 Emergency Release Rope and...

Page 40: ...10 Universal Motor 041A7767 11 Travel Module 041D7742 5 12 Cover 041D8411 13 Logic Board 050ACTWF 14 Logic Board End Panel 041A8198 Contact Information Before calling please have the model number of t...