background image

LIMITED WARRANTY

SPECIFICATIONS

The Raynor ControlHoist Optima Jackshaft type electric operator is designed for use on commercial and industrial
size sectional overhead doors and rolling doors only.

HEADROOM REQUIREMENT

SIDE ROOM REQUIREMENT

CONTROL

DOOR TYPE

ADJUSTABLE FRICTION CLUTCH

REDUCTION

OVERLOAD PROTECTION

DOOR TRAVEL

LIMIT SWITCHES

Side mount below door shaft, no additional headroom
required. Operator mounted above door shaft,
requires 32 inches above hardware headroom. See
Fig. 1, Page 4.

Requires 26 inches of side clearance out from jamb.
See Fig. 1, Page 4.

24 volt secondary control circuit as standard.

For use on lift clearance and vertical lift sectional
over-head doors requiring over 30 inches of headroom,
and rolling doors.

Provided to protect door and operator if door movement
is obstructed.

Worm gear running in oil bath. 40 to 1 ratio. Output
speed is approximately 43 RPM. Secondary reduction
is chain and sprocket.

Manual reset type for over current protection.

Operator to move door 6 to 12 inches per second.
Depending on door size, sprocket reduction and
track type.

Chain drive, screw type.

5973132-2

Under the terms of this limited warranty, for any operator components that are found to be defective upon inspection by
authorized Raynor personnel, Raynor will, at its option, repair or replace the defective door components. Labor charges for
installations or repairs shall be the responsibility of the consumer and must be performed by an authorized Raynor Dealer.

This warranty extends only to the original purchaser. This warranty is not transferable.

Raynor shall not be liable for any consequential or incidental damages.

Some states do not allow the exclusion or limitation of consequential or incidental damages, so the above limitation or
exclusion may not apply to you.

Claims for defects in material and workmanship covered by this warranty shall be made in writing with proof of purchase
to the dealer from whom the product was purchased or call Raynor at 1-800-4-RAYNOR within the warranty period. Raynor

may choose to have the product returned for inspection.
This warranty gives you specific legal rights. You may also have other rights, which may vary from state to state.

This warranty applies only to doors that are professionally installed by an authorized Raynor Dealer.

This warranty does not apply to any damage or deterioration caused by abuse or failure to provide reasonable and
necessary maintenance.

ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY,
ARE HEREBY EXPRESSLY EXCLUDED.

MOTOR

FREQUENCY OF OPERATION

Continuous duty rated, NEMA "C" faced, 1725 RPM.

Will handle up to 30 cycles per hour or 300 cycles per
day.

Raynor warrants the electrical operator and component parts against defects in material and workmanship for three (3)
years, on the operator only, when purchased with any model of Raynor commercial sectional or rolling door.

Raynor warrants the electrical operator and component parts for two (2) years against defects in material and workmanship.

Summary of Contents for COH

Page 1: ...Chain Hoist Special Application Jackshaft IMPORTANT PLEASE READ THESE INSTRUCTIONS BEFORE STARTING INSTALLATION IT IS IMPORTANT THAT THIS OPERATOR BE INSTALLED CORRECTLY IN ORDER TO ACHIEVE SAFE AND...

Page 2: ...y of the consumer and must be performed by an authorized Raynor Dealer This warranty extends only to the original purchaser This warranty is not transferable Raynor shall not be liable for any consequ...

Page 3: ...s 9 Do not place hands in area of pulleys V belt sprockets chain or rotating shafts 10 Install warning placard on wall next to push button 11 Attach instruction booklet to wall near push button 12 Do...

Page 4: ...ining the operator itself one drive and one driven sprocket one length of chain one control station and one package of small hardware Unpack carton being certain that all loose parts are removed befor...

Page 5: ...est results Place small drive sprocket on proper side of operator shaft as shown in Fig 3 Remove base mounting plate from operator see Fig 3 and use as a template for drilling holes in wall then re in...

Page 6: ...ator and set limit switches in this mode Once correct rotation has been established manually lower door to fully closed position Set close limit nut at desired position by depressing limit nut keeper...

Page 7: ...ten the belleville springs See Fig 6 If additional tension is required add extra belleville springs to clutch assembly WARNING Do NOT over tension clutch Note The clutch is set loose at the factory an...

Page 8: ...Power Connection Terminal Block 1 Terminal Block 2 High Voltage Wire Harness Connection LIGHT CCM NO1 SER C1NC1 NO2 C2NC2 ON OFF OPEN CLOSE ON OFF 24VDC 24VDC 24VAC 24VAC Terminal Block 3 24V DC Power...

Page 9: ...sing RD or RC wiring photo eye s or edge must be selected even though they are not required Note The photo eye or an electric edge must be monitored 5 SENSOR 2 TYPE will display there are three option...

Page 10: ...warning light is required select OFF If a warning light is required select ON Press the stop button to continue 16 If a warning light is ON WARNING TIME will display The time is set in 1 second inter...

Page 11: ...r death 8 SAVE THESE INSTRUCTIONS OPERATING INSTRUCTIONS Operating the 3 Button Control Station 1 Press OPEN button The door should move in the open direction 2 Press STOP button The door should stop...

Page 12: ...eset press reset button on outside of control box When overload trips it cuts power to the 24 volt control circuit only To reset open control box cover and press red reset button PERIODIC INSPECTION A...

Page 13: ...ng Off Stop button pressed or NOT connected On Open button sending signal pressed Off Open button is not sending signal 2 Open D12 6 I Lock D24 7 I Lock D23 On Chain hoist interlock circuit is open ch...

Page 14: ...ton to pause this countdown Sensor 1 activated This message will display anytime the board is not receiving a signal from the sensor 1 when close button is pressed Whether it is not connected activate...

Page 15: ...minate stress on rollers and cables 1 Sunlight is blocking the receiving photo eye 2 Faulty photo eyes 1 Connect Operator to power source 2 Check voltage at L1 L2 for single phase and at L1 L2 L3 for...

Page 16: ...oard Verify power consumption of the device s before installing You may have to power the device from an external power source using only the contacts of the device to activate the operator 3 The comm...

Page 17: ...use the dry contacts of that relay to activate the device If more than 3 amps of power is being consumed through the auxiliary board then damage to the board may occur 2 There is a 14 pin connector o...

Page 18: ...nger anger La Label el Door oor Safet Safety y La Label el Spring Spring Warning ning Tag ag Pu Push Button h Button Placa Placard Locate n Locate near Push Button Push Button Door oor Safet Safety y...