40
Routine Maintenance Can Prevent Tragedies
1
2
•
Starting with the door in the closed position, use the manual disconnect on the opener to disconnect
the door.
•
Look for signs of wear or damage on hinges, rollers, springs, and door panels.
•
These parts may require periodic lubrication. Check the owner’s manual for suggested maintenance.
•
If any signs of damage are evident, contact a trained door systems technician for assistance.
•
Verify the photoeye height is no higher than 6" from the garage fl oor.
•
Open and close the door manually using handles or suitable gripping points.
•
The door should move freely and without diffi culty.
•
The door should balance and stay partially open 3–4 feet above the fl oor.
•
If you detect any signs of improper operation, contact a trained door systems
technician for assistance.
•
Reconnect the opener to the door using the manual disconnect and open the door.
•
Place a 2x4 board fl at in the path of the door (1) and try to close it (2). The door
should stop when it comes in contact with the 2x4 and then reverse direction.
•
Block the photoelectric sensor by waving an object in front of the sensor and
attempt to close the door. The door should not close unless the wall-mounted push
button is manually held during operation.
•
If the opener does not perform as described, contact a trained door systems
technician for assistance.
Make monthly inspection and testing of your garage door and opener system a part of your regular routine. Review your owner’s manual for both the door and door opener. If you don’t
have the owner’s manuals, contact the manufacturer(s) and request a copy for your specifi c model(s). Look for the opener model number on the back of the power unit.
Test the opener safety features:
Test the door for proper operation:
Visually check the door and installation:
WARNING – Springs are under high tension. Only qualifi ed individuals should adjust them.