background image

27

The door should be fully 
closed if possible. Pull 
down on the emergency 
release handle and lift 
the door manually. To 
reconnect the door to the 
opener, press the door 
control push bar.

The 

lockout feature

 

prevents the trolley from 
reconnecting automatically. 
Pull the emergency release 
handle down and back 
(toward the opener). The 
door can then be raised and 
lowered manually as often 
as necessary. To disengage 
the lockout feature, pull 
the handle straight down. 
The trolley will reconnect 
on the next UP or DOWN 
operation, either manually 
or by using the door control 
or remote.

To prevent possible SERIOUS INJURY or DEATH from 
a falling garage door:
•  If possible, use emergency release handle to 

disengage trolley ONLY when garage door is 
CLOSED. Weak or broken springs or unbalanced 
door could result in an open door falling rapidly 
and/or unexpectedly.

•  NEVER use emergency release handle unless 

garage doorway is clear of persons and 
obstructions.

•  NEVER use handle to pull door open or closed. If 

rope knot becomes untied, you could fall.

Lockout position

Manual disconnect position

Using the Wall-Mounted Door Control

THE MULTI-FUNCTION DOOR CONTROL

Press the push button to open 
or close the door. Press again 
to reverse the door during the 
closing cycle or to stop the door 
while it's opening.

Light feature

Press the Light button to turn 
the opener light on or off. It will not control the opener 
lights when the door is in motion. If you turn it on and 
then activate the opener, the light will remain on for 4-1/2 
minutes. Press again to turn it off sooner. The 4-1/2 
minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2 
minutes as follows: Press and hold the Lock button until 
the light blinks (about 10 seconds). A single blink indicates 
that the timer is reset to 1-1/2 minutes. Repeat the 
procedure and the light will blink twice, resetting the timer 
to 2-1/2 minutes. Repeat again for a 3-1/2 minute interval, 
etc., up to a maximum of four blinks and 4-1/2 minutes.

Lock feature

Designed to prevent operation of the door from 
hand-held remote controls. However, the door will open 
and close from the Door Control, the Outside Keylock and 
the Keyless Entry Accessories.

To activate, press and hold the Lock button for 2 seconds. 
The push bar light will fl ash as long as the Lock feature 
is on.

To turn off, press and hold the Lock button again for 
2 seconds. The push bar light will stop fl ashing. The Lock 
feature will also turn off whenever the “learn” button on 
the motor unit panel is activated.

Additional features when used with the 3-Button 
hand-held remote

A) To control the opener lights:

In addition to operating the door, you 
may program the remote to operate 
the lights.

1.  With the door closed, press and hold a small remote 

button that you want to control the light.

2.  Press and hold the Light button on the Multi-Function 

door control.

3.  While holding the Light button, press and hold the Lock 

button on the door control.

4.  After the opener lights fl ash, release all buttons.

B) To operate one door using all three buttons on the 
hand-held remote:

You may program the remote to 
open the door with the large button, 
close it with the middle button, and 
stop the door’s movement with the 
third button.

NOTE: 

If remote is already programmed, you must fi rst 

erase all codes. See Programming.

1.  With the door closed, press and hold the large 

remote push button.

2.  Press and hold the Lock button on the door control.

3.  Press and hold the door control push bar.

4.  After the opener lights fl ash, release all buttons.

Using Your Garage Door Opener (Continued)

S

AFETY

 S

IGNAL

™ light feature:

 Lights will also turn on 

when someone walks through the open garage door. 
With a Multi-Function Door Control, this feature may be 
turned off as follows: With the opener lights off, press and 
hold the light button for 10 seconds, until the light goes 
on, then off again. To restore this feature, start with the 
opener lights on, then press and hold the light button for 
10 seconds until the light goes off, then on again.

Push 
Button

Lock 
Button

Light 
Button

To Open the Door Manually

Open

Stop

Close

Trolley
Release
Arm

Trolley
Release
Arm

Emergency
Release
Handle
(Pull Down)

Emergency
Release Handle
(Down and Back)

Summary of Contents for 3270RGD

Page 1: ...read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properly ali...

Page 2: ...age door opener 28 Having a problem 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Ke...

Page 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Page 4: ...t garage doors berglass steel aluminum door with glass panels etc See page 19 for details Header Wall Gap between oor and bottom of door must not exceed 1 4 6 mm OR Extension Spring Torsion Spring Ver...

Page 5: ...ories will depend on the model purchased If anything is missing carefully check the packing material Parts may be stuck in the foam Hardware for installation is also listed below Multi Function Door C...

Page 6: ...SERIOUS damage to opener ONLY use bolts fasteners mounted in top of motor unit ASSEMBLY STEP 2 Set the Belt Tension By hand thread the spring trolley nut on the threaded shaft until it is nger tight...

Page 7: ...er They could be caught in garage door or opener mechanisms 9 Install wall mounted garage door control within sight of the garage door out of reach of children at minimum height of 5 feet 1 5 m away f...

Page 8: ...ches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible SERIOUS INJURY or DEATH Header bracket MUST be RIGIDLY...

Page 9: ...OWN ACTUAL SIZE CEILING HEADER BRACKET INSTALLATION Extend the vertical centerline onto the ceiling as shown Center the bracket on the vertical mark no more than 6 15 cm from the wall Make sure the ar...

Page 10: ...ON STEP 4 Position the Opener Follow instructions which apply to your door type as illustrated SECTIONAL DOOR OR ONE PIECE DOOR WITH TRACK A 2x4 laid at is convenient for setting an ideal door to rail...

Page 11: ...line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to op...

Page 12: ...bottom screw allowing 1 8 3 mm to protrude above wall surface Position bottom of door control on screw head and slide down to secure Adjust screw for snug t Install top screw with care to avoid cracki...

Page 13: ...ley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly NEVER use emergency release handle unless garage doorway...

Page 14: ...compliance with ALL local electrical and building codes NEVER use an extension cord 2 wire adapter or change plug in ANY way to make it t outlet Be sure the opener is grounded If permanent wiring is r...

Page 15: ...eiving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware Be sure power is NOT connected to the garage door opener BEFORE installi...

Page 16: ...with lag screws Not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from the mounting surface Make sure all door hardware obstructions are...

Page 17: ...l wire from both sensors to the garage door opener Attach the wire to the wall and ceiling with the staples Figure 6 Option B Pre Wired Installation If your garage already has wires installed for the...

Page 18: ...ng the door will reverse If the door is already open it will not close The opener lights will blink 10 times See page 15 Figure 10 ALIGNING THE SAFETY REVERSING SENSORS Plug in the opener The indicato...

Page 19: ...depending on your door s construction Metal or lightweight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracke...

Page 20: ...he door if required for your installation Refer to the dotted line optional placement drawing HARDWARE SHOWN ACTUAL SIZE Self Threading Screw 1 4 14x5 8 Door Bracket Top of Door Inside Garage Door Bra...

Page 21: ...e up and join sections Select holes as far apart as possible to increase door arm rigidity Figure 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straigh...

Page 22: ...tton The trolley will travel to the fully closed position Figure 6 Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm connector ho...

Page 23: ...orce as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still w...

Page 24: ...by turning the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the...

Page 25: ...nt of the opener Without a properly installed safety reversing sensor persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door Without a properly installed saf...

Page 26: ...r 4 1 2 minutes or provide constant light when the Light feature on the Multi Function Door Control is activated Bulb size is A19 Bulb power is 100 watts maximum OPERATION To reduce the risk of SEVERE...

Page 27: ...signed to prevent operation of the door from hand held remote controls However the door will open and close from the Door Control the Outside Keylock and the Keyless Entry Accessories To activate pres...

Page 28: ...ite lithium grease to the rail The lithium battery should produce power for up to 5 years To replace battery use the visor clip or screwdriver blade to pry open the case as shown Insert battery positi...

Page 29: ...st after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment...

Page 30: ...t does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires Symptom Sending i...

Page 31: ...that you wish to operate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard 1 Press and hold the b...

Page 32: ...ights will blink once when the PIN has been learned Test by pressing the new PIN then press ENTER The door should move To set a temporary PIN You may authorize access by visitors or service people wit...

Page 33: ...10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A5047 1 Door bracket w clevis pin fastener 6 41A2828 Emergency release rope handle assembly 7 178B34 Straight door arm section 8 41A...

Page 34: ...11 41D3058 Universal replacement motor Complete with Motor worm bracket bearing assembly RPM sensor 12 41A5525 13 Cover 13 41A2818 Limit switch drive retainer 14 41D3452 Limit switch assembly 15 41A2...

Page 35: ...side by entering code on specially designed keyboard Also can add a temporary pass code for visitors or service persons This temporary code can be limited to a programmable number of hours or entries...

Page 36: ...OVE EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE MOTOR AND BELT WHICH ARE LIMITED IN DURATION TO THE LIFETIME LIMITED WARRANTY PERIOD FOR THE MOTOR AND BELT AND NO IMPLIED WARRANTIES WILL EXIST O...