SeaNet-Alarm Users Manual
Alarm out
SeaNet-Alarm has a detatchable 2 pin screw terminal to connect one or more alarms,
sirens or lights.
This output is protected against short circuits, has a thermal protection, an overvoltage
and overload protection and current limitation.
Nominal maximum alarm current
3.5 A
Alarm current will be limited to
7.0 A
The Alarm output is a „
Low-
Side Switch
“. Make sure to
have the alarm horn, lamp etc.
connected as shown in the
picture.
The terminal “
–
“ has to be connected to GND ( battery –12 Volt )
The alarm device will be connected between the output
terminal marked „
+
“ and
b12 Volt.