10.2 Instrument troubleshooting
Problem
Applies to
Example screenshots
Action
Low battery.
• i40 Bidata
• i40 Depth
• i40 Speed
• i40 Wind
• Recharge your vessel's battery as
soon as possible.
Blank display.
• i40 Bidata
• i40 Depth
• i40 Speed
• i40 Wind
• Check fuse / circuit breaker.
• Check power supply.
• Check SeaTalk cabling and
connector security.
Depth reading flashes when underway. • i40 Bidata
• i40 Depth
• Ensure the reading stabilizes when
clear of disturbed water (e.g. vessel
wakes, propeller wash etc.).
No data.
• i40 Bidata
• i40 Depth
• i40 Speed
• i40 Wind
• Check the condition of the
transducer cable and security of the
connections.
• Check condition of transducer face
and remove any debris.
• For i40 wind — if true wind speed
information is missing but apparent
wind is present then this could be
due to no speed information via
SeaTalk.
Troubleshooting