Item
Cable color
Signal name
1
Black
Piezoceramic –
2
Blue
Piezoc
3
Screen
0 V (shield)
i40 Speed connection
Item
Cable color
Signal name
1
Brown
Temperature 0 V
2
White
Temperature (signal)
3
Screen
Speed 0 V (shield)
4
Green
Speed (signal)
5
Red
Speed V+
i40 Wind connection
Item
Cable color
Signal name
1
Red
Rotor +
2
Blue
Rotor –
Making transducer connections
Although the transducer cable is fitted with spade connectors for
direct connection to the rear of the unit, it may be necessary to
remove these to facilitate installation, e.g. if the cable has to be
routed through narrow apertures. 1/8th spade terminals will be
required (not supplied), to replace those removed. When fitting the
new spade connectors, prepare the cables as detailed below:
1. Prepare the cable as shown in 1 above.
2. Fold back the wire strands and insert into the new spade
connector as shown in 2 above.
3. Ensure the wire strands do not extend beyond the rear of the
spade connector insulation.
4. Crimp the connector to the wire.