Chapter 2: Installation
13
Transducer Connection
A 25ft (8m) cable is supplied with the transducer. The transducer cable
connector has a nut that has been removed to aid installation. To enable you
to complete the installation without cutting the cable, ensure that any holes
you drill are large enough to accept the connector, with the nut removed
(approximately 13/16" or 21 mm).
Before attaching the transducer cable, you will need to attach the connector
nut, which is included in the transducer packaging.
The transducer cable is attached to the 7 pin male
TRANSDUCER
connector on
the connector panel of the DS600X. (See
Figure 2-3
.)
CAUTION:
•
Do not pull on the cable. This can damage the transducer wires.
•
Do not cut the transducer cable or remove the connector.
•
Do not try to shorten or splice the cable. Cutting the transducer cable will
severely reduce sonar performance.
•
If the cable is cut, it must be replaced—it cannot be repaired. Cutting the
cable will also void the warranty.
WARNING:
Removing the transducer cable from the rear of the DS600X while the
fishfinder is powered on can cause sparks. Only remove the transducer
cable after power has been removed from the DS600X.
If the transducer cable is accidentally removed while the DS600X is
powered on, remove power from the fishfinder, replace the transducer
cable, and then restore power. As a safety feature, the DS600X only
recognizes that the transducer is connected at power-up.
Summary of Contents for DS600X
Page 1: ...DS600X Digital Fishfinder Owner s Handbook Document number 81235 2 Date April 2004...
Page 2: ......
Page 10: ...x DS600 Digital Fishfinder Worldwide Support 68 Appendix A Specifications 69 Index 71...
Page 14: ...4 DS600X Digital Fishfinder...
Page 24: ...14 DS600X Digital Fishfinder...
Page 50: ...40 DS600X Digital Fishfinder...
Page 60: ...50 DS600X Digital Fishfinder Figure 5 5 Displaying Navigation Data 40 20 60 60 D6903 1...