Installation
11
Connecting the power and digital cables
The following must be observed:
• The threads of the Digital Radome digital cable external connector
should be lightly greased with “Renolit Aqua 2 Calcium” grease if
disconnected after the initial installation.
• Preferred connection of the power cable is directly to your boat’s
power distribution panel.
• Care should be taken to ensure a firm connection between the Digital
Radome’s external connector and the digital cable connector.
• The digital cable connection to the Digital Radome scanner must be
hand-tightened only.
The following diagrams show the various configurations in which the
Digital Radome scanner may be connected to your multi-function display:
Digital Radome connected directly to C-Series display
Note:
you must use a SeaTalk
hs
Crossover Coupler for direct connections.
C-Series display
Radar
D11372-1
SeaTalk
hs
Crossover
Coupler
12/24V power