background image

23

3.

 

 is switched on or off 

 

CO   Calibration locked i.e. no access
Cl = Calibration unlocked i.e. normal access.

Return to 

 display mode

Press and hold Display and   After 2 

   display returns to

depth mode.

6.5 Master/Repeater display

 

 leaves   factory   ST30 

 is 

 

 

 in Master mode.

In this mode   

 is connected to a 

 transducer and

 depth 

 

   

 bus. 

 ST30 

 can be

set as a Repeater, repeating depth 

 already on   

bus. Repeater mode is set   

Summary of Contents for Autohelm ST30 Bidata

Page 1: ...Distributed by Any reference to Raytheon or RTN in this manual should be interpreted as Raymarine The names Raytheon and RTN are owned by the Raytheon Company...

Page 2: ...TOP EDGE BLEED MASK FOR 2 COLOUR SEATALK LOGO DEPTH Operation and Installation ST 30...

Page 3: ...TOP EDGE BLEED MASK FOR 2 COLOUR SEATALK LOGO Nautech Limited Anchorage Park Portsmouth P03 5TD England Telephone 0705 693611 Fax 0705 694642...

Page 4: ...es DISPLAY DEPTH SHALLOW DEEP MIN IM UM OFFSET TM Autohelm and SeaTalk are registered Trade Marks of Nautech Limited Autohelms policy of continuous improvement and updating may change product specific...

Page 5: ...able 6 Depth transducer through hull with 10m cable and 1 8in spade connectors 7 Instrument cover 8 Operation and installation handbook 9 Daisy chain cable ST30 INSTRUMENT MOUNTING TEMPLATE 2 HOLES DR...

Page 6: ...2 3 Installation 10 Chapter 3 Fault Finding 12 Chapter 4 Maintenance 13 4 1 Instrument 13 4 2 Transducer 13 4 3 Cabling 13 4 4 Advice 13 Chapter 5 Operation 14 5 1 Display Key 14 5 2 Light Key 16 5 3...

Page 7: ...0 Depth can be used as a stand alone master instrument or be set up to repeat information from the SeaTalk bus The ST30 Depth will display the following information Water depth Shallow alarm Deep alar...

Page 8: ...normally viewed at eye level protected from physical damage at least 230mm 9in from a compass at least 500mm 20in from radio receiving equipment accessible from behind for ease of installation and ca...

Page 9: ...tor boss Note To allow protective covers to be fitted adjacent instruments should be sited not less than 6mm 0 24in from each other 116mm centre to centre min 3 Drill two 5mm 0 2in diameter holes for...

Page 10: ...ulded power plug to either SeaTalk connection on the rear of the instrument Run the free end back to the vessel s distribution panel 2 Cut the power cable to length and connect the red wire to the pos...

Page 11: ...ble that allows adjacent ST30 instruments to be linked together The daisy chain cable supplies power to adjacent instruments and allows data to be transmitted and received via the SeaTalk bus The dais...

Page 12: ...c through hull transducer This is suitable for use with Glass Reinforced Plastic GRP Steel and Aluminium hulls Wooden hull and transom mount installations require a different type of transducer Please...

Page 13: ...tallation and maintenance instructions These instructions together with the following notes should be read thoroughly before attempting to install the transducer 10 Max D630 1 The ST30 Depth transduce...

Page 14: ...ull Z118 in hull puck Z117 or retractable depth Z120 transducers are to be used the following modification must be carried out to the transducer lead 1 Using a pair of wire cutters remove the moulded...

Page 15: ...play blank No supply to instrument Check supply Check cabling and security of connectors Check circuit breaker fuse Return ST30 Depth for repair No depth information Aereated water boat wakes or prope...

Page 16: ...be used to clean the ST30 Depth instrument if the instrument is dirty clean with a soft damp cloth 4 2 Transducer Refer to the Installation and Maintenance instructions supplied with the transducer 4...

Page 17: ...depth in the units set up in calibration Feet SHALLOW DEEP MINIMUM OFFSET D643 Note The trend arrows decreasing increasing shown in the above display indicate whether the trend is towards deep or shal...

Page 18: ...LAY DEPTH SHALLOW DEEP MINIMUM OFFSET Feet D645 DISPLAY TM DEPTH SHALLOW DEEP MINIMUM OFFSET Feet D646 Note The Minimum depth display may be reset by pressing for 1 second DISPLAY TM DEPTH SHALLOW DEE...

Page 19: ...rms The ST30 Depth is equipped with visual and audible shallow and deep water alarms Both of these alarms are set in calibration see section 6 3 Any button press will silence the Shallow alarm However...

Page 20: ...th information in feet or metres To enter calibration press and hold Diiy and f After 2 seconds the display till show CM Each press of Display will cycle the unitthrough the calibration menu 6 2 Depth...

Page 21: ...ffset Shallow alarm 1 Cycle Display until the Shallod alarm is displayed 2 Press A or V to set the required depth fr 17 3 Shallow Alarm is enabled by pressing T When the alarm is on the Alarm legend w...

Page 22: ...iiiii ii i ii ii i i i Deep alarm 1 Cycle Display until Deep alarm is displayed 2 Press A or V to set the required depth i DEPTI 3 The Deep alarm is enabled by pressing 9 When the alarm is on the Ala...

Page 23: ...t measures the water depth below the transducer To display water depth below the keel or to the surface an offset must be set up A negative offset is used to reduce the displayed value and give depth...

Page 24: ...isplay until offd is selected DEPTH 2 Press A or V until the rewired offset is I I I 1 DEPTH Exii calibration To exii calibration and return to depth mode press and hdd Display and for a 2 seconds 111...

Page 25: ...liy changing the set calibration values For securii the calibrabon lock unlock feature is accessed by an extended hold down of the 4 and Dfspfay keys as follows 1 Press and hold Diiplay and T for 14 s...

Page 26: ...and a After 2 seconds the display returns to depth mode 6 5 Master Repeater display As It leaves the factory the ST30 Dapth is set to operate in Master mode In this mode the inshument is connected to...

Page 27: ...ndholdDispbyand uuntilthedisplayshowsaUandatwa figure number 2 Press Display to show the current operating mode 3 Press A to change mode r0 Master mode rl Repeater mode Note When the ST30 Depi31 is se...

Page 28: ...Chapter6 Calibra6on 25 Return to normal display mode Press and hold Display and After 2 seconds UE display returns to depth mode...

Page 29: ...eraturerange 0 to 70 deg C Shallow alarm 1 to 10m 0 1 increments 3 to 33ft 1ft increments Deep alarm 3 to 120m 1m increments 10 to 400ft 10ft increments Offset 4 to 4m 0 1 increments 9 9 to 9 9ft 0 1...

Page 30: ...TOP EDGE BLEED MASK FOR 2 COLOUR SEATALK LOGO Nautech Limited Anchorage Park Portsmouth P03 5TD England Telephone 0705 693611 Fax 0705 694642...

Page 31: ...TOP EDGE BLEED MASK FOR 2 COLOUR SEATALK LOGO Nautech Limited Anchorage Park Portsmouth P03 5TD England Telephone 0705 693611 Fax 0705 694642...

Reviews: