8  

WARNING

:

 To maintain the IP rating of the product the multicore auxiliary 

cable must be waterproofed and terminated appropriately even if it is not in 
use. 

Telemetry Input (Orange & Purple) 
As default the telemetry input will be wired together so that the 
unit turns  on/off automatically via the photocell. If required to be 
activated by PIR or alarm system, connect to appropriate, volt-
free or TTL input. Volt free input/dry contact: Non polarity 
sensitive, short circuit = light on 
TTL input: Orange = TTL +ve, Purple = TTL –ve (GND) 0V = Light on, 
3V = Light off 

Photocell following output (White & Yellow) 
Volt free output - normally open (day) to normally closed (night). 
Connect direct to camera if required to control switchover of 
day/night cameras. 

Step 4 : Interchangeable Lenses: Changing the Angle  

Step 1 

Unscrew 

baseplate 

Step 2 

Remove 

baseplate 

Step 3 

Remove / 

Replace diffuser 

lens 

Step 4 

Replace 

baseplate 

& tighten

www.ray

led

.com

Ray

LED

  Tel : +

33

(0)

 4 58 00 15 74

Summary of Contents for VAR2-POE-i2-1

Page 1: ...nd Operating Mode Page 12 VARIO Remote Controller VRC Page 14 PIN Function Guide Page 16 Manual Control Push Buttons Page 22 Disabling Manual Buttons Page 23 Power Up Functionality Re Set Options Page 24 Re enabling Manual Buttons and Remote Controller Page 25 Standard Bracketry Page 26 Specifications Table Page 28 Troubleshooting Page 32 Quick reference tables for Manual Button Control and Remote...

Page 2: ... distance is 1500mm Max IR EHV Exposure Hazard Value 69 of Risk Group 2 Limit at 200mm from the illuminator Eye Safety White Light Variants Caution EN62471 Risk Group 2 Classification Possible hazardous optical radiation emitted from this product May be harmful to eyes do not stare at the lamp Hazard distance is 1500mm Max WL EHV Exposure Hazard Value 68 of Risk Group 2 Limit at 200mm from the lam...

Page 3: ...ng Contact volt free output Photocell Auxiliary Cable Premium Variants only Optional 24V DC power input red ve black ve External Input volt free or TTL orange TTL ve purple TTL GND External Output volt free yellow white CAT 5 Cable for PoE Interchangeable Lensing PoE Detection Resistance Selection Switch Please note base plate has been removed for illustrative purposes Please note Waterproof conne...

Page 4: ...patible with your PoE equipment 24 9KΩ is factory default Premium Variants For low voltage non PoE apply 24V DC to red and black cores of auxiliary cable Connect external inputs and external output wires as required IMPORTANT Ensure PoE equipment or 24V PSU are suitably rated For 8 sized products check PoE detection resistance is set correctly Ensure Cat 5 cable and auxiliary cable are correctly t...

Page 5: ...tton Control Enabled Programming function will auto disable after 7 Days See Mode Power Up and Time Out Functionality Pg 23 Vario2 POE Complete Set Up and Installation STEP 1 Safety Information Pg 2 Step 2 Physical Installation VARIO2 PoE is delivered as standard with bracket at the bottom of the unit This can be moved to top of the unit if required www rayled com RayLED Tel 33 0 4 58 00 15 74 ...

Page 6: ...or Ensure that the PSE is sufficiently rated to power the VARIO2 PoE device as follows Model Standard and Premium PoE Requirement VAR2 POE w2 1 i2 1 i2 1 C IEEE 802 3af HP PoE 12 95W VAR2 POE w4 1 i4 1 i4 1 C i6 1 IEEE 802 3at HP PoE 25 5W VAR2 POE w8 1 i8 1 i8 1 C 4 pair PoE 51W The maximum Ethernet cable length is 100m 328 without boosting the power Ensure you make a waterproof connection to the...

Page 7: ...ce Check with your supplier of PSE equipment For 24 9 KΩ slide switch to the LEFT factory default as shown For 12 5 KΩ slide switch to the RIGHT Power from 24V DC Premium Variants Only If using low voltage power connect 24V DC to the red ve and black ve cables of the auxiliary cable For Premium variants connect external input trigger and external output as required see table and description below ...

Page 8: ...ppropriate volt free or TTL input Volt free input dry contact Non polarity sensitive short circuit light on TTL input Orange TTL ve Purple TTL ve GND 0V Light on 3V Light off Photocell following output White Yellow Volt free output normally open day to normally closed night Connect direct to camera if required to control switchover of day night cameras Step 4 Interchangeable Lenses Changing the An...

Page 9: ...120 x50 All ILS lenses will be clearly marked with the angle which they will produce when inserted into VARIO2 POE Please handle ILS lenses with care and do not touch optical film Only 1 ILS lens can be inserted into the product at any time The product cannot accommodate multiple ILS lenses at the same time We would recommend that power is turned off when replacing ILS lenses Step 5 Configuration ...

Page 10: ...22 for detail on the LED status indicator feedback for these functions LHS RHS Programming Mode and Operating Mode Factory Default On initial power up the illuminator is in Programming Mode On powering up the illuminator it automatically enters programming mode to allow the user to adjust set up and operation The programming mode automatically times out after 7 Days or until the user actively disa...

Page 11: ...ING GREEN Remote controller IR receiver problem Max VRC distance is 8m 26ft both modes RHS FLASHING AMBER Indicates unit is in programming mode Programming Mode Only RHS SOLID AMBER Indicates that a valid command is being received from the remote controller Programming Mode Only LHS FLASHING RED POE Voltage supply problem detected both modes LHS SOLID RED Illuminator fault detected both modes All ...

Page 12: ...ctions provided with VRC when supplied Note Reset button will not remove a PIN if one is present Note Unless detailed as part of the functionality if an invalid or blocked command is attempted both LEDs will flash RED www rayled com RayLED Tel 33 0 4 58 00 15 74 ...

Page 13: ...the Vario Remote Control VRC There are five buttons characters on the remote that can be used for this purpose Please see PIN Function Guide P 10 for full details on how to use the PIN function Note Unless detailed as part of the functionality if an invalid or blocked command is attempted both LEDs will flash RED www rayled com RayLED Tel 33 0 4 58 00 15 74 ...

Page 14: ...ired to complete the PIN entry There are four characters to be entered to successfully set up a PIN As you enter the characters the number of flashes will decrease until all characters are entered Note illegal characters will not be recognised and will not reduce the number of flashes When the PIN is set the illuminator will revert to Programming Mode Operation When a PIN is Set Using the remote c...

Page 15: ...or into operating mode you will not be able to go back to programming mode without recycling the power Note If you forget your PIN and need to make adjustments to the illuminator you will need to perform a full Re set This requires power recycling whilst pressing the two manual control buttons at the same time This will restore factory default settings AND remove the previously programmed PIN Both...

Page 16: ...de or Enable Remote Controller and enter Programming Mode 6 Button Enable Disable In short the LHS button selects your mode category indicated by specific behaviours of the LHS LED and the RHS button selects your chosen level setting with that pre selected mode also indicated by specific behaviours of the RHS LED The buttons are active in both programming mode and operating mode regardless of whet...

Page 17: ...s you can change the following configurations Illuminator Re set Enable Remote Controller and enter Programming Mode Disable Remote Controller and enter Operating Mode Manual Button Enable Disable Sequential presses of LHS BUTTON will cycle you through the available options to get to the required mode that you desire indicated by the LHS LED Note Unless detailed as part of the functionality if an ...

Page 18: ...g level detailed in the following section you can lock in your settings in one of two ways 1 Press the LHS BUTTON to cycle through the modes until LHS LED extinguishes showing that you are at the end of the mode loop Or 2 You can also wait 2 minutes for the illuminator to time out and the value shown by RHS LED will be stored into the illuminator memory The settings programmed by the manual push b...

Page 19: ...tor was in before selecting the manual controls The following modes are available Power Level Mode LHS LED Solid RED 20 Power Setting RHS LED 1 Flash GREEN 40 Power Setting RHS LED 2 Flashes GREEN 60 Power Setting RHS LED 3 Flashes GREEN 80 Power Setting RHS LED 4 Flashes GREEN 100 Power Setting RHS LED 5 Flashes GREEN Photocell Level Mode LHS LED Solid GREEN Low sensitivity RHS LED 1 Flash GREEN ...

Page 20: ... LED Flashing GREEN and pressing a third time momentarily will turn the LHS LED Flashing AMBER Each of these colours indicates which setting mode you are in A further momentary press of LHS Button will exit from the mode entry both LEDs will go blank for 1 second and then return to the standard indication of either operating mode or programming mode depending on which mode the illuminator was in p...

Page 21: ... Programming mode there are no restrictions Manual Control Buttons Enable Disable of LHS LED Flashing AMBER Enable Manual Button Control RHS LED Solid GREEN Disable Manual Button Control RHS LED Solid RED Note If the illuminator is in Operating Mode and the buttons have been disabled for at least 30 minutes you cannot re enable button control without recycling power if no PIN present or entering y...

Page 22: ...cognised and the indicator LEDs will not change RHS Button o The RHS button is functional with the Illuminator Configuration Mode In any other mode pushing this button will cause both indicator LEDS to flash RED Once the 30 minutes has expired the manual buttons are fully Disabled and any button push LHS or RHS will cause both indicator LEDs to flash RED Disabling the Manual Buttons Using the Remo...

Page 23: ...tton press RESET Options There are Two Re set options for resetting your VARIO2 illuminator Settings Re set Pressing and holding the RESET BUTTON on the remote control or using the manual buttons to complete a RESET will restore the factory settings to the illuminator Note If a PIN is present it will not be removed and the illuminator will return to the mode you were previously in Programming or O...

Page 24: ...ve a straight 30 mins of safety time to change your mind where you can still use the buttons to re enable button control after this time has elapsed you can enter the PIN or do a full re set 2 If you disable the remote controller you can re enable it by If no PIN Present You can use the manual buttons If the manual buttons are disabled or you do not want to use them then you need to re cycle the p...

Page 25: ...25 Standard Bracketry Supplied with the Product Model Dependant Not to scale dimensions rounded to nearest mm www rayled com RayLED Tel 33 0 4 58 00 15 74 ...

Page 26: ...30ft 35m 115ft 50m 164ft 36m 118ft 25m 82ft 18m 59ft 14m 46ft 120 45m 148ft 25m 82ft 30m 98ft 24m 79ft 18m 59ft 14m 46ft 8m 26ft Consumption 49W max 47W max 25W max 15W max 25W max 8W max 9W max Input POE POE POE Weight 1 65kg 3 61lbs 950g 2 1lbs 600g 1 3lbs Number of LED s 24 12 9 12 3 3 Environment IP66 IP66 IP66 Dimensions 135 x 180 x 68mm 5 x7 x3 100 x 135 x 66m 4 x5 x2 5 75 x 100 x 64mm 3 x4 ...

Page 27: ... 14m 46ft 8m 26ft Consumption 49W max 47W max 25W max 15W max 25W max 8W max 9W max Input POE or 24V DC POE or 24V DC POE or 24V DC Weight 1 75kg 3 85lbs 1 05Kg 2 31lbs 700g 1 54lbs Number of LED s 24 12 9 12 3 3 Environment IP66 IP66 IP66 Dimensions 135 x 180 x 68mm 5 x7 x3 100 x 135 x 66m 4 x5 x2 5 75 x 100 x 64mm 3 x4 x2 5 CAT 5 Cable Length 2 5m 2 5m 2 5m 2 5m 2 5m 2 5m 2 5m Auxillary Cable Le...

Page 28: ...uitably rated for the VARIO2 POE unit see page 7 for required ratings Check polarity of illuminator connection red ve black ve Ensure power is 24V DC If longer cables used ensure sufficient voltage is provided to allow for drops across the cable Step 2 Check Photocell and Telemetry Input Check photocell is working Cover photocell fully light should turn on Note It is sometimes difficult to see Inf...

Page 29: ... FLASH RED but extinguish and revert to the standard SOLD GREEN when the correct voltage has been restored The fault indications are non latching Normal operating mode LHS SOLID GREEN Power Applied LHS FLASHING GREEN Remote control IR received problem Max VRC distance is 8m 26ft LHS FLASHING RED Voltage supply problem detected LHS SOLID RED Illuminator LED fault detected Check unit is responding t...

Page 30: ...camera is used and that the camera switches correctly into night mode Check camera and lens Is iris fully open at night and set correctly Ensure camera is fully operational and has correct night time settings and capability Ensure correct illuminator lens angle selected for required distance check stated performance If the angle is too narrow it may cause hot spots and the aperture of the camera l...

Page 31: ... and serial number of illuminator Camera make and model Camera Lens make and model If the RayLED illuminator or remote control is still not delivering the required performance please contact us for further assistance www rayled com RayLED Tel 33 0 4 58 00 15 74 ...

Page 32: ...d Off Solid Amber On Green Off Red Factory Re set Does not Re set PIN 1 x Long Push 4 Seconds Push and Hold until both LEDs flash Amber Flashing Red After 4s Flashing Amber Solid Red After 4s Flashing Amber Reverts to Programming Mode unless a PIN is present If a PIN is present reverts to original mode before re set Disable Remote and Enter Operating Mode or Enable Remote and Enter Programming Mod...

Page 33: ...trol can be used and 2 Operating Mode when most of the remote control functions are disabled see Remote Control Instructions for more details Manual Buttons are always available in programming mode or if they have been disabled they can be enabled in programming mode Manual Buttons are available in operating mode provided they have not already been disabled The number of button pushes indicated ab...

Page 34: ...est Moon Max Timer Full Red Circle Timer Disable The unit will NOT accept any invalid characters and the countdown will not reduce If valid characters are entered in the wrong order when entering a PIN the unit will accept the input and reduce the countdown but at the end of the countdown the illuminator will show an error and the procedure to enter a valid PIN will have to be repeated Action Requ...

Page 35: ...lid Amber Flashing Red counts down the No of valid characters required Flashing Amber Stays in Programming Mode after PIN created or changed Enter existing PIN Prog Mode Press Status Button for 4 seconds Enter valid PIN character x 4 Green Intermitte nt Flashing Red Green Green Solid Amber Flashing Green counts down the No of characters required Flashing Amber Enters Programming Mode after valid P...

Page 36: ...36 VA2 POE 16 1 0 www rayled com RAYLED VIRTUAVIA 2 RUE MARCEL BENOIT 38000 GRENOBLE FRANCE www RayLED com Tél 33 4 58 00 15 74 Fax 33 9 55 70 03 53 ...