03/2014
SUPERSCAN-IIE
Mirrors & Objectives
Scan mirrors and objectives with optimized mounts are available for all typical laser types, wavelengths, power densities, focal
lengths and working fields. Customer specific configurations are also possible. Please contact the RAYLASE support team for
specific information and possible combinations on +49-8153-8898-0 or email
Options
The SUPERSCAN II scan heads provide two types of water-tempering connections for the electronics and galvanometer
scanners, Straight [W] connectors and 90° [W2] connectors along with air-cooling [A] of the deflection mirrors. This ensures
constant working conditions and excellent long-term stability, thus guaranteeing reliable operation even in high-laser-power
applications.
Auto calibration option [K] available for all SUPERSCAN II models with reference sensors for automatic drift compensation
which ensures process stability.
BE and SC mirrors allow for higher speed performance due to the lightweight mirror substrates and optimized mirror mounts.
Air flushing Specifications
Specifications
Flow rate
Air Pressure
Air
Clean air free of water & oil
100 l / min
1.0 - 1.5 bar
Water Tempering Specifications
Specifications
Flow rate
Pressure loss
Water
1)
Clean tap water with additives
2 l / min
0.3 bar
Temperature
22-28°C
4 l / min
0.4 bar
Pressure
2-5 bar
6 l / min
0.7 bar
(1) Caution:
When using cooling water including deionized water, suitable additives must be used to prevent the growth of
algae and protect the aluminium parts against corrosion.
Additive recommendations:
Standard industrial applications e.g. CCL105 (NALCO)
Food & beverage, packaging applications:
e.g. polypropylene glycol e.g. DOWCAL N. (Dow Chemical).
Please consult your additive supplier for dosage information