7. Repair guide
8. Others
•
Have your product repaired by a qualified person.
•
This electric product is in accordance with the relevant safety requirements. Repairs should
Only be carried out by qualified persons using original spare parts; otherwise this may result in considera-
ble danger to the user.
•
Please contact the store which you bought the product for after sale services if question.
TROUBLE
PROBABLE CAUSE
SUGGEST REMEDY
• Fuse or circuit breaker blown.
•
Check main and branch circuit fuses
or
Fan will not
• Loose power line connections to
circuit breakers.
the fan.
• Check line wire connections to fan.
start
• Speed controller not in correct
• Check speed controller’s position.
position.
• Top canopy touching ceiling.
• Lower canopy from ceiling to ensure
• Loose fan blades screws.
•
minimum 3mm clearance.
• Ceiling fan not secured against
Re-tighten all screws on fan blades
but
Fan sounds
ceiling.
•
never over-tighten.
noisy
• Incorrect speed controller.
Re-tighten all screws in the hanging
bracket or plate.
• Change the controller to the one
supplied.
Mechanical
• Allow
at least for 8 hours setting-in
noise
period
.
• Fan blades are not horizontal to • Measure from ceiling to tips of blades,
ceiling.
then rotate fan so all blades are
• Blade screws are loose.
checked for equal height from ceiling
Fan wobbles
( not adjustments may be made by
slight pressure up or down on blade
holders).
• Make
sure all screws are securely
fastened.
EN
AW_23037_UserGuide_VO2_2020.pdf 8 23/11/20 9:55