Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide RFL-QCW300/3000
6
Remove all the contents from the packing case. Take extra care when taking the unit out of
the packing case to ensure that the feeding fiber is not snagged and damaged. A comprehensive
packing list is sent with the laser. Check all items against the list and contact Raycus
immediately if there is any missing item or evident damage to the unit. Do not attempt to install
or operate the laser, if there is any evidence or suspected damage to the unit.
It is recommended to keep the packing materials, as they will be necessary if you ever need
to ship the unit back for service at a later date.
CAUTION
:
The fiber optic cable and fiber connector are precise optic instrument,
any vibration, twist or excessive bend will damage the instrument.
2.4
Operation Environment
Table 2 shows basic operation environment of this device:
Table 2 Basic operation environment of the Laser
Power Source
48±10% VDC
Power Capacity
> 3000 watts
Environment
Flat with no vibration and shock
Sufficient airflow
Temperature
0
℃
~40
℃
Humidity
<80%
Weight
<60kg
Warning:
a)
Make sure the instrument is properly grounded before using it.
b)
There are no user serviceable parts, equipment or assemblies inside the product. All
service and maintenance shall be performed by qualified Raycus personnel. In order to
avoid electric shock, please do not break the seal or uncover the cap. Failure to comply
with this instruction is not within the guarantee range.
受
控
武汉锐科