@2021 Raycus Corporation
12
4.
Operation Regulations
4.1.
Pre-inspection
a)
Make sure the device appearance is in good condition and the output fiber is neither
excessively bended nor broken.
b)
Make sure signal line of laser and marking system are properly connected.
4.2.
a)
Starting procedures
Please make sure the control system is on before you turn on the fiber laser. Only after
at least 1 minute since the power turned on, the subsequent operations can be proceeded.
b)
Frequency set introductions
The frequency setting range is from 1 kHz to 2000 kHz(The actual frequency range of
each pulse width is showed in the Table 3).
c)
Laser marking checking
For the device initial testing, first turn the power down to zero without turning on the
marking system after the device is successfully started. Then draw a quadrate, marking
continuously while slowly increasing the power from 1% to 100% at the same time.
Meanwhile, use a ceramic material to observe the laser and the laser should become
stronger, otherwise shut down the device and check.
If operating normally, the marking system can be used in common order afterwards.
4.3.
Cautions
a)
Marking frequency must be in the range of 1 kHz to 2000 kHz(The actual frequency
range of each pulse width is showed in the Table 3).
b)
It should not modify the frequency while marking.
c)
Stop marking first before shutting down the device, then turn the power down to zero
and cut the power off.