2
Wuhan Raycus Fiber Laser Technologies CO., LTD.
P200MX Pulsed Fiber Laser User Instruction V1
5. When the laser is in operation, it is strictly prohibited to install the output collimator.
6. The laser has seven fans at the tail plate for heat dissipation, which must ensure
sufficient airflow for heat dissipation. The laser fan works in a blowing direction, i.e.
the direction of airflow is from the fan position to the laser fiber delivery cable
connector position. At least 10 cm of ventilation space is left in front and behind the
laser. If the laser is installed in a cabinet with its own cooling fan, it must be ensured
that the cabinet fan airflow direction is not opposite to the laser airflow direction.
7. Do not look directly at the fiber delivery cable connector, in the operation of the
machine to ensure long-term wear to prevent 1μm wavelength laser protective eye
environment.
8. Maximum use time without pulse is 50 x 10
-6
seconds.
1.4. Specifications
Table 2 200MX pulsed fiber laser specifications
No.
Characteristic
Test Condition
Value
Uni
t
1
Operating Mode
/
Pulsed
/
2
Average output power @
350ns
RR=1kHz Pmax
2≤P≤3
W
RR=100kHz Pmax
100≤P≤104
W
RR=130kHz Pmax
201≤P≤208
W
RR=600kHz Pmax
201≤P≤208
W
3
Output power adjustment
range
/
1-100
%
4
Central emission wavelength
P=Pmax
1064
nm
5
Emission Bandwith
P=Pmax
≤5
nm
6
Output power instability
After 5Hrs/ P=Pmax
≤5
%
7
Laser switching ON time
RR=130kHz P=0
~
90% Pmax
<100
us
8
Laser switching OFF time
RR=130kHz
P=100%
~
10%Pmax
<30
us
9
Pulse repetition frequency
See table 3
1-4000
kHz
10
Output beam
diameter@86% power
P=Pmax
6-8
mm
11
Red guide laser power
0.2-1.0
mW
12
Pulse duration
P=Pmax
(
10/20/30/60/100/200/250/350
)
ns
13
Beam quality
,
M
2
P=Pmax
≤
1.8
/
14
Maximum pulse energy
P=Pmax
1.5
mJ
15
Output fiber cable length
3
m