background image

2

Wuhan Raycus Fiber Laser Technologies CO., LTD.

P200MX Pulsed Fiber Laser User Instruction V1

5. When the laser is in operation, it is strictly prohibited to install the output collimator.
6. The laser has seven fans at the tail plate for heat dissipation, which must ensure

sufficient airflow for heat dissipation. The laser fan works in a blowing direction, i.e.
the direction of airflow is from the fan position to the laser fiber delivery cable
connector position. At least 10 cm of ventilation space is left in front and behind the
laser. If the laser is installed in a cabinet with its own cooling fan, it must be ensured
that the cabinet fan airflow direction is not opposite to the laser airflow direction.

7. Do not look directly at the fiber delivery cable connector, in the operation of the

machine to ensure long-term wear to prevent 1μm wavelength laser protective eye
environment.

8. Maximum use time without pulse is 50 x 10

-6

seconds.

1.4. Specifications

Table 2 200MX pulsed fiber laser specifications

No.

Characteristic

Test Condition

Value

Uni

t

1

Operating Mode

/

Pulsed

/

2

Average output power @

350ns

RR=1kHz Pmax

2≤P≤3

W

RR=100kHz Pmax

100≤P≤104

W

RR=130kHz Pmax

201≤P≤208

W

RR=600kHz Pmax

201≤P≤208

W

3

Output power adjustment

range

/

1-100

%

4

Central emission wavelength

P=Pmax

1064

nm

5

Emission Bandwith

P=Pmax

≤5

nm

6

Output power instability

After 5Hrs/ P=Pmax

≤5

%

7

Laser switching ON time

RR=130kHz P=0

90% Pmax

<100

us

8

Laser switching OFF time

RR=130kHz

P=100%

10%Pmax

<30

us

9

Pulse repetition frequency

See table 3

1-4000

kHz

10

Output beam

diameter@86% power

P=Pmax

6-8

mm

11

Red guide laser power

0.2-1.0

mW

12

Pulse duration

P=Pmax

10/20/30/60/100/200/250/350

ns

13

Beam quality

M

2

P=Pmax

1.8

/

14

Maximum pulse energy

P=Pmax

1.5

mJ

15

Output fiber cable length

3

m

Summary of Contents for RFL-P200MX

Page 1: ...Wuhan Raycus Fiber Laser Technologies CO LTD P200MX Pulsed Fiber Laser User Instruction V1 User Instruction RFL P200MX Wuhan Raycus Fiber Laser Technologies CO Ltd 2021...

Page 2: ...lying the power to the device please make sure that the correct voltage of 48V DC is connected and the anode and cathode are right Incorrect polarity or voltage will damage the device The device emits...

Page 3: ...Environmental requirements and cautions 1 1 4 Specifications 2 2 Installation 4 2 1 Installation dimensions 4 2 2 Method of installation 4 3 Control Interface 6 3 1 Pre inspection 11 3 2 Operation pr...

Page 4: ...own in Table 1 Table 1 Items Quantity Notes Fiber Laser module 1 Factory inspection report 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 48V DC 1V power source The pow...

Page 5: ...the machine to ensure long term wear to prevent 1 m wavelength laser protective eye environment 8 Maximum use time without pulse is 50 x 10 6 seconds 1 4 Specifications Table 2 200MX pulsed fiber lase...

Page 6: ...MX No Pulse duration waveform ns PRFmin kHZ Min frequency Base frequency PRF0 kHZ Base frequency corresponding power w PRFmax kHZ Maximum frequency Pmax W Maximum frequency corresponding power Emax mJ...

Page 7: ...of laser module Unit mm 2 Optical isolator output head size diagram Figure 2 Dimension drawing of output isolator Unit mm The output head of the isolator is subject to the final factory product 2 2 M...

Page 8: ...de 200W laser is about 800W please ensure that the output power of 48V DC power supply reaches more than 1000W 4 Make sure that the interface of the external controller matches the laser and the contr...

Page 9: ...us Check the details in Table 6 17 VCC 5VDC power supply input Providing power for inside isolate chip of DB25 to ensure that the input and output signal are valid 18 Pre emission signal MO PA pre out...

Page 10: ...h High System failure Spare High High Low Standby Spare High High High Standby Note Pin 12 is the backup signal and is always high 3 Pin 17 is a 5V input voltage which is used to supply power to the i...

Page 11: ...ata on the rising edge of SCLK 3 Serial clock Serial clock highest frequency 100K 14 GND Digital GND 16 SO Serial clock output the laser outputs data on the rising edge of SCLK 22 Interface Enable Hig...

Page 12: ...3 3 The operation steps of laser marking after the marking machine is turned on checks For the device initial testing first turn the power down to 10 without turning on the marking system after the d...

Page 13: ...ce damages due to excessive use or not following the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the device An...