Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL- RFL-C8000S
27
mode is turned on, the optical power is controlled by an external signal, and the power setting
function of the software should be set to a disabled state. When the external modulation mode is
turned on, the frequency, pulse width and duty cycle are controlled by the external modulation
signal, and the function of the software to set the frequency, pulse width and duty cycle should
be set to the disabled state.
Control the light: control to turn on or off the laser emission or laser enable. Only when the
laser has a ready signal, can it be controlled normally, otherwise the buttons for turning on and
off the laser are set to the disabled state. When the external control light enable is turned off, and
the external modulation mode or internal modulation mode is turned on, the "laser enable" is
displayed, otherwise, the "laser emission" is displayed.
Status display: Including emergency stop, laser enable, Interlock logic normal, Interlock1
closed, Interlock2 closed, power ramp up and down, program mode, program execution, program
execution completed, program execution abnormal and other most commonly used laser states,
and machine Internal ambient temperature, internal ambient humidity, dew point, external 0-10V,
light output frequency, light output duty cycle, light pulse width, laser water flow, output optical
cable water flow and other data. These status and data refresh time intervals should not exceed
300ms.
Laser usage time display: including today's turn-on time, today's light-emitting time,
cumulative turn-on time, and cumulative light-emitting time.
4.7.3 The alarm interface
All the alarm information of the current laser is displayed on the alarm interface, and the
alarm information is updated in real time.