Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C4000S-CE
23
10mA
supply is started
24 Laser emission
LASER
Digital output 24VdC >10mA 100ms High=Laser is emission
Caution: Please check the control voltage level and ensure that the level is in
accordance with the requirements. Over voltage and voltage ripple may damage
the product.
The Service Security Interface is pin 1-4 and pin2-3
,
of CTRL-INTERFACE.If the pin 2-3
and pin 1-4 are disconnected, the laser will immediately stop emitting light, and the laser Ready
signal output will change to low level. Be sure to short-circuit pin 2-3 and pin 1-4 before using
the laser. If it is not short-circuited, the laser will display InterLock alarm after power-on.
Interlock interface must not be connected to active signal, otherwise it
will cause interface damage and laser alarm.
4.4.2 TCP/IP Interface Configuration
Thedefault IP address of this product is 192.168.0.10, only supporting UDP communication.
The laser listens for connection on port is 8098, and the command must be sent in a single data
string.
Table 8 Thepin definitions of Ethernet interface
PIN
FUNCTION
DESCRIPTION
1
TX+
T
2
TX-
TRANSMIT-
3
RX+
4
N/C
NONE
5
N/C
NONE
6
RX-
RECEIVE-
7
N/C
NONE
8
N/C
NONE
For better communication stability, recommend to use this interface first.
Table 9
The default IP address of the laser
The default IP address of the laser
IP address
192.168.0.10