Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus 1000W
~
2000W laser
29
4.6.1 Wiring in external RS-232
Fi
gure 18 Wiring in external RS-232 mode
4.6.2 External RS232 mode operation procedure
(
1
)
Short-circuit DB25 control interface’s PIN17 and PIN18, Select external
control mode.
(
2
)
Wait 10s, The internal circuit initialization phase is complete; Ensure
disconnect DB25 control interface’s PIN7 and PIN19, Avoid the laser enter AD
mode.
(
3
)
Connect AC power, The laser’s front panel ‘Power’ is on.
(
4
)
Wait 10s, The internal circuit initialization phase is complete;
(
5
)
Setting the laser power by upper computer software;
(
6
)
The external MOD interface provides modulating signal for the laser;
(
7
)
Enable the laser through one of the following ways
: