H908 Installation Instructions – End Seal
1
2
3
4
5
6
7
8
9
Note: The end seal is designed to be installed only once; it cannot be removed from the heating cable once installed. Do not use until ready for final installation.
1"
R
R
2"
R
• Remove the
outer jacket.
• Do not cut or
damage inner
jacket.
• Push the braid back 2 inches from the cable end.
• Slide the braid up against the end seal and secure with the
6-inch length of tape provided.
R
• Firmly push end seal onto the cable (at least 1 1/2 inches).
Some gel may ooze out.
• Do not twist or try to remove the end seal during or after
insertion. Do not reuse an end seal.
• Firmly push end seal onto the cable (at least 1 1/2 inches).
Some gel may ooze out.
• Do not twist or try to remove the end seal during or after
insertion. Do not reuse an end seal.
• Unravel and remove exposed braid.
• Cleanly cut off the end of the cable.
• Score down and around outer jacket
1 inch from the end.
1
End Seal for H612, H622
3
2
2
4
• Cleanly cut off the end
of the cable.
1
End Seal for H311, H611, H621
3