background image

The firebricks fitted to the Rayburn 345W are of first
quality manufacture, and providing the cooker has been
installed and used correctly will have a reasonable life.
They are, however, expendable items and in time will
require renewal.
Replacement bricks either in sets or singly can be
obtained from your Rayburn distributor. Always quote the
manufacturing number.
The manufacturing number, which will be found fixed to
the appliance, should be quoted if any question arises in
connection with the Rayburn 345W Cooker.

The cooker has been designed to provide a satisfactory
supply of domestic hot water with or without a limited
amount of heating with a normal day’s cooking providing
the cooker is kept alight overnight and the system
complete with lagged cylinder conforms to the installation
instructions.

Always use a qualified service/heating engineer when
servicing is required. Use only authorised replacement
parts. Do not make unauthorised modifications.

Any air inlet grilles must be maintained so that they are
free from blockage.

Failing to maintain your cooker properly can lead to a
chimney fire. Chimney fires occur when combustible
deposits on the inner walls of the chimney ignite. These
combustible deposits, called “creosote”, are a natural by-
product of wood burning. A fire hazard exists if 1/4” of
creosote (or more) coats the inner walls of the chimney.

Properly installed and operated, this cooker will not emit
fumes.
Occasional fumes from de-ashing and re-fuelling may occur
but persistent fume emission must not be tolerated.
If fume emission does persist, then the following immediate
action should be taken:-
a) Open doors and windows to ventilate room.
b) Let the fire out or remove lit fuel from cooker.
c) Check for flue or chimney blockage, and clean if 

required.

d) Do not attempt to relight fire until cause of fumes has 

been identified, and if necessary, seek  professional   
advice

Part Number

Description

No Reqd

QWX

Boiler Thermostat

1

1/16182 T

Bottomgrate bars top

5

1/16182 B

Bottomgrate bars bottom

5

3/16272

Oven side firebricks

2

4/16273

Firebox side top firebricks

1

3/16271

Front firebrick

1

3/16274

Removable boiler face
rear firebrick

1

3/16275

Removable boiler face
side firebrick

2

3/18172

Grate Baffle

2

Replacement parts if required are always available ex-
works. Write to us should any difficulty be encountered in
obtaining them from your usual supplier.

SMOKE/SMELL EMITTED DURING INITIAL USAGE

Some parts of the cooker have been coated with a light
covering of protective oil. During initial operation of the
cooker, this may cause smoke/smell to be emitted and is
normal and not a fault with the appliance, it is therefore
advisable to open  doors and or windows to allow for
ventilation.
Lift the insulating lids to prevent staining the linings.

FIREBRICK REPLACEMENT

HOT WATER SERVICE

SERVICING

8

FUME EMISSION WARNING

SPARES LIST

Summary of Contents for Heatranger 345W

Page 1: ...and central heating The thermostatically controlled hot water boiler can be operated independently of the cooker and will provide hot water for central heating and domestic use normal setting for winter usage whilst manually operated spinwheel control on the front of the ashpit door will provide heat for cooking and domestic hot water normal setting for summer usage The cooker boiler flueway dampe...

Page 2: ...upply will reduce its intensity If there is a damper in the chimney connector plug or close the opening 4 If a fire extinguisher is available open the appliance door just enough to insert the nozzle of a 10lb dry chemical fire extinguisher rated for Class ABC fires Discharge the entire content of the fire extinguisher into the appliance and shut the door 5 If possible wet down the roof and other o...

Page 3: ...sed cooking Close and lock firebox door Push flue chamber damper back to position which has been found to give desired burning rate All fuels Using a Gas Poker a Check flue pipe is free of blockage b Open firebox door c Open ashpit door d De ash Fig 8 and remove clinker door Fig 10 Insert flat bayonet type gas poker on top of bottomgrate bars e Remove ashpan and empty Fig 9 f Open flue chamber dam...

Page 4: ...TEMPERATURE BY DIRECTING THE HEAT TO WATER Cooking Only Set the spinwheel open The precise amount will be shown by experience with the appliance 2 3 turns will do to start After setting the cooker boiler damper knob to C set the flue chamber damper fully open after refuelling and reset to position which has been found by practical experience to give the best results Do not try to obtain a fast inc...

Page 5: ...m and minimise burning rates NOTE THE PRECISE AMOUNT OF OPENING DEPENDS ON THE CHIMNEY DRAUGHT AND THE TYPE CONDITION OF WOOD TO BE BURNT THIS MAY TAKE 2 OR 3 DAYS TO ASCERTAIN 1 If the fuel in the firebox is exhausted prematurely the overnight chimney draught must be reduced by increasing the opening setting of the flue chamber door using the flue dilution lever 2 If the fuel does not burn but di...

Page 6: ... that required close the spinwheel to approximately one turn open Thereafter control the temperature of the oven by adjusting the spinwheel NOTE THE METHOD SHOULD PROVE SUCCESSFUL IN ALMOST ALL CASES BUT IF CLOSING THE FLUE CHAMBER DAMPER CAUSES THE FIRE TO SMOKE IT SHOULD BE OPENED GRADUALLY UNTIL THE SMOKING STOPS To reduce top heat in the oven adjust the cooker boiler damper knob gradually away...

Page 7: ...essary This should not be done whilst the cooker is hot DO NOT USE ABRASIVE PADS OVEN CLEANER OR CLEANERS CONTAINING CITRIC ACID ON ENAMELLED SURFACES IMPORTANT NOTE Aga recommend Vitreous Enamel Association approved cleaners for cleaning the vitreous enamelled surfaces of this product But they are unsuitable for use on chrome and stainless steel components including the hand rails and their brack...

Page 8: ...ats the inner walls of the chimney Properly installed and operated this cooker will not emit fumes Occasional fumes from de ashing and re fuelling may occur but persistent fume emission must not be tolerated If fume emission does persist then the following immediate action should be taken a Open doors and windows to ventilate room b Let the fire out or remove lit fuel from cooker c Check for flue ...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...policy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described at any time Manufactured by Aga Station Road Ketley Telford Shropshire TF1 5AQ England www aga web co uk www agacookshop co uk www agalinks com ...