Wear Proper Clothing.  

Do not wear loose clothing or jewelry, which may get 

caught in rotating parts. Tie back long hair.

 

 

 

Maintain the Unit.  

Inspect periodically for damaged or worn parts. Follow 

the instructions for maintenance. Don’t use if the power cord, motor, switch, 
or other parts are in poor condition. Don’t use if the unit has been dropped or 
damaged. Have a qualified service person inspect and replace parts when 
necessary. 

 

 

For Laboratory Use Only.  

The Foster Model Trimmer is intended for use by 

trained professional laboratory personnel only. 

 
 

INSTALLATION 

 
Place the model trimmer in a suitable counter top location next to a sink and near 
a water source. 
 
Water is supplied to your Foster model trimmer through a flexible polyethylene 
hose, which is fitted with a 1/4" male pipefitting.  If the available water source is 
other than a 1/4" female pipe fitting, an adapter must be obtained to complete the 
installation.  A local plumbing supply will usually have the required adapter. 
 
NOTE:  It is recommended that you do NOT use copper tubing to connect the 
model trimmer to the water supply. The problem with copper tubing is that it is 
not flexible.  This nullifies the feature of the hinged door because the hose must 
flex when opening the door.  
 
Water is discharge from the model trimmer through a 24" x 1” ID flexible hose.  
Be sure that the hose slopes downward to the drain allowing gravity to drain the 
model trimmer. 
 
Longer lengths of both water supply and drain hose are available from Ray 
Foster Dental Equipment if needed. 

 
 

PREVENTIVE MAINTENANCE 

 

FLUSH THE MODEL TRIMMER DAILY 

Your Foster model trimmer is a workhorse in the dental laboratory. It requires 
daily flushing and cleaning to prevent gypsum buildup and clogging. At the end of 
each use allow the motor to remain on and open the water adjustment to 
maximum for about 20 seconds. Turn the water off and allow the motor to run for 
an additional 10 seconds. Wipe the exterior of the model trimmer off at the end of 
each workday. 
 

Summary of Contents for MT10

Page 1: ... MT12 and MT15 Operating and Maintenance Instructions Sales Service and Technical Assistance Call Toll Free 800 654 4519 Ray Foster Dental Equipment 5421 Commercial Drive Huntington Beach CA 92649 714 897 7795 Fax 714 898 6013 ...

Page 2: ...the country of destination Use only this power cord or one that is approved for use in your country Plug into a Branch Circuit with 16A Circuit Breaker To reduce the risk of fire and to protect the units electrical system plug into a branch circuit with a 16 amp circuit breaker Disconnect the Power Cord Before performing any maintenance or repairs turn the unit off and unplug the power cord to pre...

Page 3: ... complete the installation A local plumbing supply will usually have the required adapter NOTE It is recommended that you do NOT use copper tubing to connect the model trimmer to the water supply The problem with copper tubing is that it is not flexible This nullifies the feature of the hinged door because the hose must flex when opening the door Water is discharge from the model trimmer through a...

Page 4: ...hich are inscribed on the identification plate located on the front of the Lab Master Model Trimmer EXCESSIVE VIBRATION Excess vibration from your model trimmer is a result of one or both of the following 1 An imbalance in the aluminum back plate as a result of accumulation of plaster and stone on the back 2 An out of balance abrasive wheel due to stone build up and or wear or an improperly balanc...

Page 5: ...N M096 Cork Gasket C from the backside of the attach button and replace it with the new gasket included with all Foster replacement wheels If only reversing the existing wheel or using a wheel from a source other that Ray Foster make sure that the existing cork gasket is in good condition if not a new one is needed This is essential in preventing slippage of the abrasive wheel 3 Install the new re...

Page 6: ... your 12 Foster Model Trimmer to an Orthodontic Model Trimmer capable of trimming accurate and attractive study models Back Plate Removal Tool Cat No M816 If the Aluminum Back Plate P N M221 M222 must be removed for imbalance corrections repairs etc a Back Plate Removal Tool is essential Simple illustrated instructions included Splash Shield Cat No M005 Protect your face and clothing from splatter...

Page 7: ...PARTS DIAGRAM ...

Page 8: ...M T sold as set only with Base Casting M241 Door for 10 M T sold as set only with Base Casting 18 M018 Water Spray Tube Valve Assembly M019 Water Spray Tube Valve Assembly 19 M244 Plastic Knob Tray Secure 20 M245 Washer Nylon 21 M117 Water Supply Hose 3 Feet 22 M108 Door Lock Bolt 23 M095 Lock Button with Screws Gasket 24 M096 Lock Button Gasket 25 M247 Standard Work Tray for 10 M T M248 Standard ...

Page 9: ...rt together with proof of date of purchase must be delivered freight prepaid to the factory in Huntington Beach California At its option Ray Foster Dental Equipment Company will replace or repair the defect free of charge providing the Model Trimmer has not been subjected to abuse neglect damage or used in a capacity other than which was intended Ray Foster Dental Equipment 5421 Commercial Dr Hunt...

Reviews: