RV-M7 Technical Manual
21
5.6 CONFIG Button
If certain parameters within the modem are modified in a manner that causes the modem to
cease functioning or if the user cannot enter the command mode via the “+++” method
described above, there is a small push button internal to the
M7
modem to assist in this case.
This CONFIG button may be pressed at any time, and forces the modem into a known
operational state. The CONFIG button is located inside the modem. Remove the rear cover,
exposing the two circuit boards. The button is in the center of the lower circuit board as shown
below.
The default settings that the modem will revert to when the CONFIG button is pressed are:
1.
Serial port 9600 baud, 8 data bits 1 stop, no parity
2.
ATCT setting set to 60000 (60 second time-out)
3.
Serial port on the front of the unit in RS-232 mode, 9600bps, N/8/1.
If the unit was configured for RS-485, RS-422, or Ethernet, you must disconnect other
devices and use an RS-232 device to configure the M7.
Summary of Contents for RV-M7
Page 13: ...RV M7 Technical Manual 13...
Page 30: ...RV M7 Technical Manual 30...