M7 GX Technical Manual
6
Raveon Technologies Corp.
ATHP
Channel Number
– Select separate channels to minimize
interference between multiple sets of modules operating in the
same vicinity.
Range: 1 - 6
1
ATMK
Address Mask
– Configures local and global address space. Each
digit may be a 0,1,2,3,4,5,6,7,8,9.
Range: 0000 - FFFF
FFFF
ATMY
Unit Address
– Configures the individual; address for this unit.
Each digit may be a 0,1,2,3,4,5,6,7,8,9.
Range: 0000 - FFFF
1234
ATPO
RF Power Output
. Set or show the RF power output setting. Value
is in percent, from 0% to 100%. Use and RF wattmeter to confirm
the power setting, and adjust the % accordingly to obtain the
desired RF power level.
0-100
100
ATR2
Over-The-Air bit rate
- This is the data rate the radio uses to send data over the
air.
All RF modems in the network must use the same over-the-air baud
rate
. Refer to section
Error! Reference source not found.
for information on
how to set the OTA baud rate.
Range:
0 = 800
7 = 5142 2L
5 = 9600 2L
3 = 4800
1 = 1200
8 = 9600 4L
6 = 19200 4L
4 = 8000 4L
2 = 2400
9 = 2000 2L
3
ATRV
Disable Remote Access
– When enabled (set to a 0), the modem will respond
to over-the-air RPR requests, Pings, and over-the-air commands.
0 = Remote Access on
1 = Remote Access disabled
1
ATSL
Serial Number
– Reads and returns a unique serial number for
thjs unit.
Read Only
1 - 999999999
unique
ATSH
or
SHOW
Show –
Display the configuration of the modem. This will return a
page of ASCII characters, showing the main configuration
parameters.
none
None
ATST
Statistics –
Show the unit’s operational statistics. See Statistics
section of user manual.
0, 1,2, 3, 4, or 5
None
ATVB
Read DC input Voltage
– Returns the DC input voltage reading, in
mV (12500 = 12.5VDC input).
None
none
ATVR
Firmware Version
– Returns firmware version currently loaded on
the module.
Read Only, 3 characters
Current version
REPEAT n
Enable/Disable Store and Forward Repeating –
0=disabled, 1 –
enabled (repeat everything)
0 or 1
0 (Off)
PING
Ping another modem.
Format is PING xxxx, where xxxx is the ID
of the modem to ping. If remote access is enabled on xxxx, it will
respond.
XXXX
-
SHOW
Show/display
an overview of the radio’s configuration.
None
-
** indicates values that are calibrated in the factory and are unit-specific. If the “Radio Type”
is changed, these will need to be re-calibrated.