background image

7

Screen Icons & Symbols

Icon Name Description

When the 

Cursor Lock icon

 is active, Viper is in 

the auto-pan mode.  Select this mode when 
running a job.

The 

Information icon

 is only available when you 

are not running a job and you have selected the 
Main tab on the Viper console, or when you have 
selected the Scout tab when in a job.

The 

Prescription icon

 is only available when on 

the Rx tab (if a prescription map had been 
previously loaded) or the Cov tab.

The 

Pan icon

 is used to move screen information 

up/down or left/right.

The 

Zoom Out icon

 zooms the map area 

displayed out to view a larger area on the map.

The 

Zoom In icon

 zooms into the map area 

display and allows more detailed viewing of 
information contained within the display.

The 

Zoom Extents icon

 allows you to quickly 

bring all map information back on to the display.

Icon Name Description

Thumbs Up:

 System is normal and all operating 

conditions are met.

Caution:

 There is a system alert.  User should 

investigate cause of condition and correct it.

Red 'X':

 The system is down and requires 

immediate attention.  This problem must be 
corrected before proceeding with application.

Map
Symbols

Status
Symbols

Summary of Contents for viper

Page 1: ...VIPER Quick Reference Guide Version 2 08...

Page 2: ...1 Basic Startup 1 Press the Power button to turn on the Viper system...

Page 3: ...e manual in its entirety before using Viper 5 Do power the DGPS receiver and the Raven console or CANBus system before powering Viper 6 Don t turn Viper off when in a job without properly closing the...

Page 4: ...3 Main Screen Areas See the screen below and the corresponding numbers on the next page for a description of each screen area 1 4 6 10 8 7 11 5 2 3 9...

Page 5: ...s Available for CAN systems only 7 Booms Booms turn green when on gray when off Press in this area to configure AccuBoom Control 8 AutoBoom A s turn green when on gray when off Back ground turns red i...

Page 6: ...5 CAN Controller Status Screen Areas See the screen below and the corresponding numbers on the next page for a description of each screen area 1 2 3 4 5 6 7 8...

Page 7: ...ta Box 2 More user configuration settings Press in this area to access and or change the user configuration 5 Pressure Area Dual pressure readouts for two different systems Press in this area to calib...

Page 8: ...ove screen information up down or left right The Zoom Out icon zooms the map area displayed out to view a larger area on the map The Zoom In icon zooms into the map area display and allows more detail...

Page 9: ...ress the Application Rates Area 2 Press the Node you want to set change 3 Enter Target Rate Press Next to change other Nodes or OK to save changes and close Important You can only set Application Rate...

Page 10: ...9 Profiles Saving a Profile 1 Select Menu then Setup Local Profile and Save Profile 2 Type a Profile name and press OK...

Page 11: ...10 Loading a Saved Profile 1 Select Menu then Setup Local Profile and Load Profile 2 Select a profile from the list...

Page 12: ...11 Starting a New Job 1 Select Menu Start Job then New Job 2 Type in a Job Name select a Swath Pattern if the Guidance Option has been installed and enter the number of products...

Page 13: ...lick Browse to find a Rx Map file Select the file and click OK 7 Click on the Rate Field outlined in red below and click Next 8 Type in a Rate Conversion if necessary and click OK Note The steps above...

Page 14: ...13 Adding to Existing Jobs 1 Select Menu Start Job From File then Add to Job 2 Select Existing Job and press OK Then press Menu and Cont Job to un pause the job...

Page 15: ...ol 2 Press Tally Registers 3 Press Next 4 Press Next again Type in a value for the Tank Volume and then press Set Press Next Do the same process for all nodes if needed and press OK when finished Pres...

Page 16: ...15 Marking a Field Boundary 1 Press the Scout tab and then Record 2 Press Zone 3 The Record Field Feature Screen Displays Select Field Boundary choose your options and press OK...

Page 17: ...2 Select the GPS setting 3 Press OK CAN Startup If the results show Not Found for all of your nodes press the Retry CAN Init button If you still have CAN issues see Chapter 2 in the Viper Installation...

Page 18: ...17 AccuBoom Setup 1 Press the Booms Area 2 Enter Look Ahead values and press Next 3 Select the booms to control and press OK...

Page 19: ...e center of the AutoBoom Area 2 Select Autoboom ON and UltraGlide for mode 3 Press the Calibrate button 4 Press Cal Left and wait for left boom calibration to complete then press Cal Right and wait fo...

Page 20: ...19 AutoBoom PowerGlide Plus Calibration 1 Press in the center of the AutoBoom Area 2 Select Autoboom ON and PowerGlide Plus for mode 3 Press the Calibrate button 4 Press Cal Boom button 5 Press OK...

Page 21: ...20 On Screen Lightbar 1 Press Menu Setup then Lightbar 2 Select a Lightbar to use 3 Press Next to set it up 4 Press OK when finished...

Page 22: ...s inserted properly and the storage card door is closed Important You must use a flashdisk with a minimum of 128 MB and a maximum of 512 MB for the Viper console The flashdisk must be a SanDisk brand...

Page 23: ...Buttons with arrows go to sub menus Buttons without arrows go directly to selection screens MAIN MENU START JOB SUBMENU MAPS SUBMENU SETUP SUBMENU FROM FILE SUBMENU LOCAL SUBMENU PROFILE SUBMENU RX MA...

Page 24: ...vided are the property of Raven Industries Inc and may only be used as authorized by Raven Industries Inc All rights reserved under the copyright laws Raven Industries Flow Controls Division P O Box 5...

Reviews: