CHAPTER
3
Manual No. 016-0171-219 Rev E
7
CHAPTER 3
USING THE SWITCH PRO
SYSTEM
SWITCH PRO NODES
The Switch Pro built-in AccuBoom, boom/speed, and single product nodes are automatically recognized by the
Envizio Pro or Viper Pro field computer.
The built-in single product node will always be detected as product or control channel 1 on the field computer. If
additional product control nodes are connected to the system, make sure to re-address these nodes on the Envizio
Pro or Viper Pro field computer.
Refer to the Envizio Pro or Viper Pro Installation & Operation Manual for information on addressing the CAN
nodes connected to a CANbus system.
NOTE:
To ensure proper operation of the Switch Pro system, make sure the field computer has the latest
version of software. Switch Pro requires Viper Pro version 2.52 or higher or Envizio Pro version 1.00C
or higher.
Refer to the field computer Installation & Operation Manual for more information on software
updates.
USING SWITCH PRO
LOGIC POWER LED
The logic power LED displays the status of logic power. This LED is switched by the Envizio Pro or Viper Pro power
and illuminate green when logic power is On.
INCREASE/DECREASE FLOW SWITCH
For products in automatic control mode, the Increase/Decrease flow switch is used to increase or decrease the
target rate of products selected and actively displayed on the Envizio Pro or Viper Pro field computer. In order for
this switch to work properly, a ‘Rate Bump’ (Rate +/-) value must be programmed for each product or control
channel. See the Envizio Pro or Viper Pro operation manual for details on programming this feature.
For products in manual mode, holding the Increase/Decrease flow switch will open or close the control valve,
increasing or decreasing the flow of product. See the Envizio Pro or Viper Pro Installation & Operation Manual for
instructions on programming products or switching a product to manual mode.
Summary of Contents for Switch Pro
Page 17: ...13 FIGURE 2 Viper Pro with Switch Pro for SCS 440 450 Cabled Systems...
Page 19: ...15 FIGURE 4 Viper Pro with Switch Pro for SCS 4400 Cabled Systems...
Page 21: ...17 FIGURE 6 Viper Pro with Switch Pro Combo Cable for SCS 440 450 Cabled Systems...
Page 23: ...19 FIGURE 8 Viper Pro with Switch Pro Combo Cable for SCS 4400 Cabled Systems...
Page 24: ...APPENDIX B 20 Raven Switch Pro Installation Reference Manual...
Page 28: ...APPENDIX C 24 Raven Switch Pro Installation Reference Manual...
Page 30: ...Index 22 Raven Switch Pro Installation Reference Manual...