Chapter 5
32
SCS 4000/5000 Series™ Installation & Operation Manual
Console Programming
Edit Mode
During normal operation of the SCS console, pressing the calibration keys will access the selected calibration
screen. In order to program numerical values into the SCS console, use the Edit mode. To enter Edit mode:
1.
Press the ENTER key. The default or existing value will be cleared and the screen will display an “E” on the
far right side of the screen.
2.
Key in the desired value for the current setting. For example, press “2” “1” “2” “3” to enter a value of 2123.
3.
Press the ENTER key to accept the keyed value and return to normal operation.
Note:
During the initial console programming, pressing ENTER accepts the keyed value and advances
to the next calibration screen.
Calibration Keys
The calibration keys allow the operator to program the SCS console and calibrate the system to the specific
application equipment. See the
section on page 32 for information on programming the SCS
console using the Edit mode.
Boom Cal
Press the BOOM CAL button to display the boom calibration screen. This screen allows the operator to view
and edit boom section widths for up to ten boom sections.
1.
Press the BOOM CAL button. The Boom 1 Cal screen is displayed.
2.
Press the UP or DOWN ARROW keys to view the boom section screens for additional sections.
3.
Use the Edit mode to enter or edit boom section widths. If a boom section is not used or not needed, enter
“0” as the value for that boom section’s boom cal.
Speed Cal
Press SPEED CAL to display the current speed calibration value used to determine vehicle speed. For more
information, refer to the
Meter Cal
Press the METER CAL button to display the following settings for the selected node.
For Liquid Products:
Press the METER CAL button to display the current programmed meter calibration
value used to calculate the volume per minute, rate, and total gallons for each product being applied. The
METER CAL value is printed on the tag on the flow meter.
Note:
For more information, refer to the Chapter 12, Flow Meter Maintenance & Adjustment Procedure.
For Granular Products:
Press the METER CAL button to display either the product density or spreader
constant for the selected product node. Continue pressing the METER CAL button to toggle between the
spreader constant and product density settings for the selected node.