Manual No. 016-0171-079 Rev F
13
ACCUBOOM INSTALLATION
FIGURE 8. Boom Valve Wires Connected
7. Connect the AccuBoom 1+ wire to the parallel positive boom switch wire.
8. Locate the AccuBoom wire connector from the 10-wire bundle for the 1- boom switch.
9. Connect AccuBoom 1- wire to the negative boom switch wire that was disconnected in step 4.
NOTE:
Refer to Table 3 below when connecting the AccuBoom cable to the boom switches.
TABLE 3. Boom Switch Connections
10. Locate the AccuBoom wire connector from the 5-wire bundle for the first boom switch.
11. Connect the AccuBoom wire to the positive terminal on the boom switch.
NOTE:
The positive terminal is where the positive parallel wire connector was previously connected.
12. Repeat the steps above for the remaining boom sections, referring to the appropriate table for the number of
boom sections present.
AccuBoom Wire Color
3-Boom System
Boom Number
5-Boom System
Boom Number
Black or Gray
1
1
Brown
2
2
Blue
3
3
Black/White
Not Connected
4
Brown/White
Not Connected
5
1- Wire
Connected to the
Negative Boom
Switch Wire
1+ Wire Connected
to the Parallel
Positive Boom Switch
Wire
Summary of Contents for SCS 460
Page 2: ......
Page 4: ...Table of Contents ii SpraCoupe 3000 4000 with SCS 460 Console AccuBoom Installation Manual ...
Page 22: ...CHAPTER 3 18 SpraCoupe 3000 4000 with SCS 460 Console AccuBoom Installation Manual ...
Page 24: ...CHAPTER 4 20 SpraCoupe 3000 4000 with SCS 460 Console AccuBoom Installation Manual ...
Page 26: ...CHAPTER 5 22 SpraCoupe 3000 4000 with SCS 460 Console AccuBoom Installation Manual ...
Page 28: ...Index 24 SpraCoupe 3000 4000 with SCS 460 Console AccuBoom Installation Manual ...