Calibration: Calibration Wizard
13
CALIBRATION
FIGURE 8. Scale Setup
22.Enter the calibration number for the scale. Refer to Chapter 6,
, for manufacturer scale
calibration numbers.
FIGURE 9. Scale Setup
NOTE:
The manufacturer scale calibration numbers are an initial starting point for the scale calibration. It is
highly recommended to verify the scale calibration with a known weight of at least 25% of the total
scale capacity, after initial scale calibration, to ensure scale accuracy.
23.Enter the number of pickups which the sensor reads per revolution of the shaft as the RPM 1 Calibration
Number.
NOTE:
If the number of pickups is changed, this value must be changed accordingly.
24.Enter an initial value for RPM 1 Low Limit.
NOTE:
Refer to Chapter 6,
, for assistance with setting an initial RPM 1 Low Limit value.