![Raven OmniSeed Quick Reference Manual Download Page 8](http://html.mh-extra.com/html/raven/omniseed/omniseed_quick-reference-manual_788986008.webp)
7
Setting Application Rates
1. Touch the
Application Rates Area
at the bottom of the main screen.
2. Touch the displayed
Target Rate
value for the specific product node or control
channel to set/change.
3. Use the on-screen keypad to enter the target rate for the selected node or
channel.
Note:
Changes made to the target rate or rate bump values will not take affect
until the
OK
button is selected.
4. Touch the
Rate +/-
value for a product node or control channel and use the on-
screen keypad to enter the rate bump value for the specific node or control
channel.
5. Enable the
Inc/Dec Switch
option to allow the operator to use the INC/DEC
switch on the Raven CAN switch box to increase or decrease the target rate by
the rate bump value entered for the product node or control channel.
Note:
Operating the INC/DEC switch will increase or decrease all nodes or
channels with the
Inc/Dec Switch
option selected at the same time.
6. Change other nodes as necessary or touch
OK
to save the displayed settings
and return to the main screen.