System Setup: System Settings Tab
39
SYSTEM SETUP
To recalibrate the turn compensation feature:
1. Move the equipment to a known level location.
2. Open the UT Menu and select the RCM - Sprayer Menu button.
3. Select the Tools Menu softkey along the right side of the display.
4. Select the System Settings tab along the top of the display.
5. Select the Calibrate button, and then select the Redetect Orientation button. The system will recalibrate the
ECU and set the ECU orientation.
BOOM RECIRCULATION
NOTE:
The boom recirculation feature requires boom plumbing and electrical harnessing to
be compatible with this feature. If direct injection products are detected on the
system, the boom recirculation feature cannot be enabled.
This feature must be unlocked and enabled by editing or creating a new machine profile through the
profile wizard.
The recirculation button is displayed in the lower portion of the home page for product 1 for the main
product tank.
When this feature is enabled, a recirculation valve will allow product to circulate from the main product tank,
through the boom system, and back to the main tank using the main product pump. The recirculation can be
manually or automatically enabled when no sections are enabled for applying product (active section width is
zero).
When enabled, each section valve opens sequentially beginning with the outermost section valves and
progressing toward the center of the boom. Once all sections have recirculated for the set auto-operation time for
each section group, the recirculation sequence will repeat until the recirculation system is shut off or active
product application resumes.
Select the Section Auto-Operation Time button to enter or adjust the section recirculation times as needed to
ensure each section is recirculated adequately.
When this feature is enabled, the product pump is enabled, and the active section width is zero (no sections
applying product), select recirculation button in the lower portion of the home page to initiate boom recirculation.
AUTO-RECIRCULATION
Enable the auto recirculate option to allow the system to automatically start the recirculation sequence when the
active section application width is zero (all sections turned off). If the auto recirculate feature is not enabled, the
operator must activate recirculation manually through a button on the UT.
NOTE:
Whether set for manual or automatic recirculation, recirculation will automatically turn off when
spraying resumes.
RCM - Sprayer Menu Tools Menu
System
Settings
UT Menu
User Settings
Calibrate
Boom
Recirculation
Summary of Contents for Command FLEX II
Page 20: ...CHAPTER 2 10 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Page 30: ...CHAPTER 3 20 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Page 54: ...CHAPTER 4 44 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Page 58: ...CHAPTER 5 48 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Page 68: ...CHAPTER 6 58 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Page 118: ...APPENDIX A 108 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Page 122: ...APPENDIX B 112 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Page 134: ...APPENDIX D 124 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Page 142: ...APPENDIX F 132 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...