AccuFlow™ Vortex and AccuFlow™ HP+ Installation: Vapor Port Assembly
37
ACCUFLOW™ VORTEX AND ACCUFLOW™ HP+ INSTALLATION
FIGURE 27. Using the Emergency Shut-Off Rope
VAPOR PORT ASSEMBLY
FIGURE 28. Vapor Port Assembly
1. Apply PTFE thread sealant to all threaded joints.
2. Install the vapor hose fitting into the vapor port openings.
WARNING
Anhydrous ammonia can cause severe burning,
blindness, or death. Always work upwind of an
implement with the AccuFlow system. If the
emergency shut-off rope cannot be routed to the
vehicle’s cab, make sure to orient the vehicle to
allow the rope to be pulled from a location
upwind of the implement.
Emergency
Shut-Off Rope
Wind
Direction
Hose Barb
Fitting
Tee Fitting