![Raven 47860A-600 User Manual Download Page 11](http://html.mh-extra.com/html/raven/47860a-600/47860a-600_user-manual_789050011.webp)
Raven Electronics Corporation
4655 Longley Lane
Reno, NV 89502
Page 10 of 10
3.2 System-Wide Settings
Parameter
Path
Setting
Description
multicastVoting
ravenInfo.voterConfig.multicastVoting
1
0 = do not transmit on all channels
1 = multicast voted audio on all transmit channels
voteHoldOff
ravenInfo.voterConfig.voteHoldOff
10
Propagation time, in 5ms increments, for all vote receivers
to wait before a vote election occurs. 10 = 50ms
freeVote
ravenInfo.voterConfig.freeVote
2
Time, in 50ms increments, that each receiver can fight for
the vote election after the voteHoldOff timer expires. 2 =
100ms
voteLock
ravenInfo.voterConfig.voteLock
0
Time, in 50ms increments, that an elected vote receiver is
guaranteed a vote period. A setting of 0 allows any
channels to be elected without a wait period. A value of
65535 will lock the vote on a single channel for the duration
of the transmission and no other channel can be elected.
Individual channels also have their own vote period setting
which is set to 500ms by default and begins when this timer
expires.
3.3 Channel Specific Settings
Each receiver/transmitter channel has specific settings that can be manipulated via telnet. The configuration path for
each channel follows the format of {path}.{setting}:
Path = ravenInfo.m150.port[X]. where ‘X’ is channels 0 – 5.
To set the votedB on the first voter port one would use the following syntax:
Setconfig ravenInfo.m150.port[0].voteDB 2
Parameter
Setting
Description
voteDB
3
The difference in SNR results, in dB that this channel must achieve to be elected as
the voted channel.
faultTimeoutPeriod
200
The time, in 50ms increments, where this channel enters receiver fault when no
audio and no status tone is detected. 200 = 10 seconds.
votePeriod
10
Time, in 50ms increments, that this channel must remain voted before another
channel can be elected as the voted channel. 10 = 500ms
disableVote
0
0 = this channel can be voted.
1 = this channel will never be voted.
disableVoteOnCOR
1
1 = When COR is detected on this channel (pins 7,8), the channel can no longer be
voted.
0 = This channel can always be voted regardless of COR condition.
unsquelchMode
0
0 = voting begins on loss of status tone.
1 = voting begins on loss detection of COR on pins 7,8.
2 = voting begins on VOX (not recommended for most applications).
statusTone
16
16 = 2175Hz
14 = 1950
13 = 1850
useKeyingTonesForTransmit
1
1 = standard EIA keying tones are used to key the transmitter of this port.
0 = PTT/wireline on pins 3 and 6 are used to key the transmitter of this port.