CHAPTER 2 INSTALLING and SETTING UP THE UNIT
before powering up the Unit. If any cable or connector damage is discovered
while the Unit is operating, the Unit should be powered down and the damage
repaired immediately.
The Unit accepts 90-264 VAC, 47-63 Hz AC power via the AC Power Connector (located on rear panel of the
RFMOW V2 chassis). The panel connector is an IEC-320-C14 type. Use a right angle type plug and secure
it with the Velcro cord retainer.
Grounding to the user equipment rack shall consist of a grounding cable attached to the RFMOW V2
grounding stud on the rear panel of the chassis.
SETUP AND PREPARATION FOR USE
Install the RFMOW V2 by performing the steps:
Tools Needed:
•
3/8”
Nut
Driver
•
1/8” Flat-Tip Screwdriver
•
#2 Phillips Screwdriver
Install the Unit into the equipment rack. Refer to page 18 for rear panel connector locations.
1. Attach the Grounding Cable to the Grounding Stud on the rear panel (Item 19) and
tighten with a 3/8” nut driver.
2. Plug the power cord into the AC Power Input Connector on the rear panel (Item 18).
Secure the power cord with the Velcro cord retainer.
3. Attach the Modem Control Cable to J5 on the rear panel and tighten with a 1/8” Flat-Tip
screwdriver.
4. Attach the Modem Data Cable to J2 on the rear panel and tighten with a 1/8” Flat-Tip
screwdriver.
5. Attach the Secure Voice Unit Cable to J1 on the rear panel and tighten with a 1/8” Flat-
Tip screwdriver.
6. Attach the Modem Output cables (not supplied) to the TX IN and TX OUT BNC
connectors. This places the internal RF Attenuator in the Modem RF Output path.
7. Plug the Ethernet Cable (not supplied) into the Ethernet Port on the rear panel (Item 1)
(if used).
8. Plug the USB Cable (not supplied) into the USB Port on the rear panel (item 2)(if used).
9. Place the RFMOW V2 in to the equipment rack.
10. Place rack screws in the four mounting holes and tighten to the rack using a #2 Phillips
screwdriver (or other appropriate tool if not using Phillips head screws).
4