Ravelli HR EVO SMART Use And Maintenance Manual Download Page 16

HR EVØ SMART Tank Operation and Maintenance Manual

Pag.16 

Rev.0  18/05/2020

TECHNICAL CHARACTERISTICS 

Minimum clearances from combustible materials
A 500 mm

150 mm

B 500 mm

150 mm

C 100 mm

100

D 1000 mm

> 800 mm

 

 

The distances also apply when the tank is mounted 

additional right of the boiler

ADDITIONAL 

TANK 

BOILER

Measurements 

Unit of measurement

Height  

mm 

1550

Width

mm 

723

Depth

mm 

755

Empty weight

kg

105

Electrical power

absorbed

W

92

 680 

 723 

 1550 

 755 

Via Kupfer,31 25036 Palazzolo S/O 

- BRESCIA - ITALY 

TANK HR EVØ SMART

CODICE DISEGNO / REV

AICO S.p.a.

TOLLERANZE GENERALI SECONDO LA CLASSE UNI EN 22768-mK

 

GENERAL TOLERANCES AS PER UNI EN 22768-mK

STATO

FORMATO

TUTTE LE QUOTE MANCANTI SONO DA 

RICAVARE DAL MODELLO 3D

 ALL THE MISSING MEASUREMENTS CAN 

BE FOUND IN THE 3D MODEL

SCALA

DISEGNATO

MASSA

CONTROLLATO

DATA

GRUPPO DI APPARTENENZA

TIPOLOGIA

FOGLIO

1:10

A3

A0001AR01

13/06/2019

Assieme Assemblato

P.Belotti

-

P.Belotti

Proprietà della Società 

AICO S.p.A.

 Senza autorizzazione scritta della stessa, il presente 

disegno non potrà essere utilizzato per la costruzione dell’oggetto rappresentato né venire 
comunicato a terzi o riprodotto. La Società proprietaria tutela i propri diritti a rigore di legge.                                                                                         
All proprietary rights reserved by 

AICO S.p.A.

 This drawing shall not be reproduced or in any 

way utilized for the manufacture of the component of unit herein illustrated and must not be 
released to other parties without written consent. Any infringement will be legally pursued.

- Kg

DENOMINAZIONE

1 / 1 

Summary of Contents for HR EVO SMART

Page 1: ...MANUALE D USO E MANUTENZIONE USE AND MAINTENANCE MANUAL MANUEL D UTILISATION ET D ENTRETIEN Serbatoio aggiuntivo Additional tank R servoir suppl mentaire HR EV SMART...

Page 2: ...re il presente manuale in luogo idoneo non mettere da parte questo manuale senza averlo letto Installazioni scorrette manutenzioni non effettuate correttamente uso improprio del prodotto sollevano il...

Page 3: ...acciamento manomissioni errori di installazione La garanzia decade se anche una sola prescrizione riportata in questo manuale non viene rispettata Non sono coperti da garanzia i refrattari della camer...

Page 4: ...zione sull accessorio Eseguire installazione collegamento elettrico collaudo e manutenzione del serbatoio a fianco della caldaia a pellet da un tecnico qualificato e o autorizzato In caso di anomalie...

Page 5: ...ASUREMENTS CAN BE FOUND IN THE 3D MODEL SCALA DISEGNATO MASSA CONTROLLATO DATA GRUPPO DI APPARTENENZA TIPOLOGIA FOGLIO 1 10 A3 A0001AR01 13 06 2019 Assieme Assemblato P Belotti P Belotti Propriet dell...

Page 6: ...ia Dimensioni 99 x 55 5mm Formato file pdf vettoriale coralDRAW X5 File stufa orizzontale Touch slim cdr Personalizzazione per Micronova MICRONOVA S R L Disegnatore Michele Rossetti 18 04 2014 V 2 0 G...

Page 7: ...o la capacit di sopportare l assorbimento massimo sia della caldaia sia del serbatoio La caldaia deve essere opportunamente distanziata da materiali infiammabili o combustibili con intercapedini d ari...

Page 8: ...icare la taratura dei parametri dedicati al funzionamen del serbatoio aggiuntivo A B C D E F G H J K L M N P R T 21 21 20 20 19 19 18 18 17 17 16 16 15 15 14 14 13 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6...

Page 9: ...ERAN LINEARE ANGOL x2 1 2 23 22 21 20 19 18 17 16 15 14 13 12 11 x2 Togliere le 4 viti evidenziate fig 1 2 per smontare coperchio superiore e pannello posteriore fig 3 4 23 23 22 22 21 21 20 20 19 19...

Page 10: ...fig 9 quindi togliere le quattro viti per smontare la placchetta fig 10 7 8 Togliere le 2 viti evidenziate fig 8 per smontare il collare che fissa la coclea 19 18 17 16 15 14 13 12 11 x2 11 12 Svitare...

Page 11: ...2 1 2 0 1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 x2 F G H J K L M N P R T 2 4 2 3 2 2 2 1 2 0 1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 x5 2 2 2 1 2 0 1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 F G H J K L M N P...

Page 12: ...arecchiatura similare Ai sensi dell art 13 del Decreto Legislativo n 151 del 25 luglio 2005 di attuazione della Direttiva 2002 96 CE del 23 Febbraio 2003 sui Rifiuti di Apparecchiature Elettriche ed E...

Page 13: ...ep this manual in a suitable location do not discard it without reading it Incorrect installation maintenance and improper use of the product relieve the Manufacturer of all liability deriving from us...

Page 14: ...installation errors The warranty becomes null and void even if only one requirement in this manual is not complied with The following are not covered by warranty the combustion chamber refractory sto...

Page 15: ...t installation electrical connection testing and maintenance of the hopper next to the pellet boiler from a qualified and or authorized technician In case of malfunctions the boiler and its tank can b...

Page 16: ...TATO FORMATO TUTTE LE QUOTE MANCANTI SONO DA RICAVARE DAL MODELLO 3D ALL THE MISSING MEASUREMENTS CAN BE FOUND IN THE 3D MODEL SCALA DISEGNATO MASSA CONTROLLATO DATA GRUPPO DI APPARTENENZA TIPOLOGIA F...

Page 17: ...5mm Formato file pdf vettoriale coralDRAW X5 File stufa orizzontale Touch slim cdr Personalizzazione per Micronova MICRONOVA S R L Disegnatore Michele Rossetti 18 04 2014 V 2 0 Grigio tortora non con...

Page 18: ...ckets have the capacity to withstand the maximum absorption of both the boiler and the tank The boiler must be suitably spaced from flammable or combustible materials with air cavities or through the...

Page 19: ...chnician must check the calibration of the parameters dedicated to the operation of the additional tank A B C D E F G H J K L M N P R T 21 21 20 20 19 19 18 18 17 17 16 16 15 15 14 14 13 13 12 12 11 1...

Page 20: ...PR FABB Qual SE NON QUOTE FINITUR TOLLER LINEA ANG x2 1 2 23 22 21 20 19 18 17 16 15 14 13 12 11 x2 Remove the 4 highlighted screws fig 1 2 to remove the top cover and rear panel fig 3 4 23 22 21 20 1...

Page 21: ...ove the auger fig 9 and then remove the four screws to remove the plate fig 10 7 8 Remove the 2 highlighted screws fig 8 to remove the collar that secures the auger 19 18 17 16 15 14 13 12 11 x2 11 12...

Page 22: ...res fig16 the protection plates fig17 the rear panel fig18 and the top cover fig19 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 x4 2 4 2 3 2 2 2 1 2 0 1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 x2 F G H J K L M N P R T 2 4...

Page 23: ...urchasing a new similar appliance Pursuant to Article 13 of Legislative Decree No 151 of July 25 2005 implementing Directive 2002 96 EC of 23 February 2003 on Waste Electrical and Electronic Equipment...

Page 24: ...n le nettoyage l entretien etc Conserver ce manuel dans un endroit appropri ne pas mettre ce manuel de c t sans l avoir lu Les installations incorrectes les entretiens effectu s incorrectement ainsi q...

Page 25: ...x de fabrication condition que le produit n ait pas subi de ruptures caus es par un usage incorrect la n gligence un branchement incorrect des manipulations frauduleuses des erreurs d installation La...

Page 26: ...travaux sur l accessoire Effectuer l installation le raccordement lectrique les essais et la maintenance de la tr mie c t de la chaudi re pellets par un technicien qualifi et ou autoris En cas de dys...

Page 27: ...NG MEASUREMENTS CAN BE FOUND IN THE 3D MODEL SCALA DISEGNATO MASSA CONTROLLATO DATA GRUPPO DI APPARTENENZA TIPOLOGIA FOGLIO 1 10 A3 A0001AR01 13 06 2019 Assieme Assemblato P Belotti P Belotti Propriet...

Page 28: ...rte de la chaudi re Dimensioni 99 x 55 5mm Formato file pdf vettoriale coralDRAW X5 File stufa orizzontale Touch slim cdr Personalizzazione per Micronova MICRONOVA S R L Disegnatore Michele Rossetti 1...

Page 29: ...trique et les prises ont la capacit de supporter l absorption maximale de la chaudi re et du r servoir La chaudi re doit tre convenablement espac e des mat riaux inflammables ou combustibles par des c...

Page 30: ...lectrique effectu le technicien qualifi de Ravelli doit v rifier le calibrage des param tres d di s au fonctionnement du r servoir suppl mentaire A B C D E F G H J K L M N P R T 21 21 20 20 19 19 18 1...

Page 31: ...QUOTE IN FINITURA TOLLERAN LINEARE ANGOL x2 1 2 23 22 21 20 19 18 17 16 15 14 13 12 11 x2 Retirez les 4 vis surlign es fig 1 2 pour enlever le couvercle sup rieur et le panneau arri re fig 3 4 23 23...

Page 32: ...10 Retirez la vis sans fin fig 9 puis retirez les quatre vis pour d monter la plaque fig 10 7 8 Retirez les 2 vis surlign es fig 8 pour enlever le collier qui fixe la vi sans fins 19 18 17 16 15 14 1...

Page 33: ...s plaques de protection fig17 le panneau arri re fig18 et le couvercle sup rieur fig19 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 x4 2 4 2 3 2 2 2 1 2 0 1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 x2 F G H J K L M N P R T...

Page 34: ...s de l achat d un nouvel appareil similaire Conform ment l article 13 du d cret l gislatif n 151 du 25 juillet 2005 portant application de la directive 2002 96 CE du 23 f vrier 2003 relative aux d che...

Page 35: ...DATA DATE INTERVENTO INTERVENTION MANUTENZIONE MAINTENANCE...

Page 36: ...booklet and considers itself free to make any variations to the features of its products without notice La Soci t Ravelli ne s assume aucune responsabilit pour d ventuelles erreurs du pr sent opuscul...

Reviews: