Use and maintenance manual
Dual 9 super
Rev.1 25/01/2019
EN
Pag.69
Cleaning the pellet tank
To clean the pellet tank, proceed as follows:
step
action
1
Periodically remove the wood sawdust accumulated on the bottom of the tank, using a vacuum cleaner.
Smoke conduit cleaning
! IMPORTANT
This operation must be carried out by a Ravelli Assistance Centre.
Schedule this type of cleaning with the Ravelli Assistance Centre.
The smoke conduit must be cleaned every 3 months.
step
action
1
Open the hatches.
2
Clean the ashes, eventually use a brush or similar and reassemble everything.
Note: the hatches are equipped with gaskets, therefore, before reassembling them, make sure that the gaskets are not
worn.
Note: The operation must be carried out with a cold stove, using an ash-type aspirator.
Extraordinary maintenance
Extraordinary maintenance activities must be carried out by staff from the Authorised Assistance Centre.
Do not wait for components to be deteriorated by use before proceeding with their replacement. Replace a worn
component before it is completely broken to prevent any damage caused by sudden component breakage.
PARTS / FREQUENCY
60- 90 DAYS
1 SEASON
Deep combustion chamber cleaning
•
Door gasket
•
Chimney
•
1
INSPECTION HATCH
GASKET
Summary of Contents for DUAL SUPER 9
Page 172: ...DATE WORK PERFORMED MAINTENANCE...
Page 173: ......