Operation Manual RAVAS Proline Touch Basic
Rev. 6
11
Weight Display
Scale-No.
W1
No. Of
Weighing Range
W1.1 … W1.3
partial weighing range for multiple-range scales.
No-Motion Symbol
Settled weight (printing / storing enabled).
Gross Weight Or
e.g. 1250
Switching from gross weight to
Net Weight
e.g. 650 Net
net weight with Tare-key.
Net Weight Symbol
Net
Scale is tared.
Unit
e.g. kg
Weight unit, selectable in calibration mode.
Auxiliary Display (switchable via Display Select Key)
Tare
12,9kgT
Display of tare weight
Gross
1000kg
Display of gross weight
Gross weight bargraph (zero to max load)
Approved weight storage
W&M approved data archive (see chapter 'Data Archive')
Firmware information
Show details of firmware version
Example for firmware information
3.1
Numeric / Alphanumeric Keyboard (Example)
Numbers and special characters can be entered via the template of the numeric keyboard. With the key
'ABC...' the layout can be switched to the template for alphabetic inputs.
With the '123...' key the layout can be
switched back to the template for numeric
inputs.