RAVAK a.s.
, Obecnická 285, 261 01 Pøíbram 1, ÈR
tel.: 318 427 111, 318 427 200, fax: 318 427 269, 318 427 278, e-mail: [email protected], www.ravak.com
BASIC MOUNTING KIT
The handle must be mounted before installation of the bathtub. It cannot be mounted afterwards!
1. PU handle Left/ Right/
2. Galvanized screw M8x50mm
3. Galvanized washer
8.5mm diameter
4. Nut M8
5. Template
Æ
1 pc
3 pcs
3 pcs
3 pcs
2 pcs
MOUNTING INSTRUCTIONS
FOR THE ROSA II HANDLE
On the ROSA II bathtub, the handle
is mounted to the middle of the
curved part of the bathtub, near the
overflow. Both ends of the handle
are shaped differently to coincide
with the curvature of the bathtub.
The handle cannot be mounted in
the opposite way.
We recommend that you test the handle in different positions until the correct position
for you has been found.
The slight springiness of the handle allows it to be pressed into the exact place against
the wall of the bathtub.
Place the handle into the desired position and with a soft pencil mark the exact shape of
the seating part of the handle onto the bathtub. Axis of the handle should be set even to
curvature of the bathtub, approximately 30 mm from the outer edge of the bathtub.
Mount the handle on the upper flat of the widened bathtub rim.
In the marked places on the inner side of the bathtub, drill holes of 3 mm in diameter.
Now, widen the holes to 8.5mm. Drill very carefully! Use only light pressure when
drilling quickly and keep the drill upright (on the same angle as the threads of the
handle).
Before final placement of the handle, place a small amount of silicone on the outer side
of the holes, under the washers.
Remove the backing paper from the template and seat the clear, self-adhering foil of
the template over the pre-marked shapes on the bathtub. Adjust it so that the shape of
the template is symmetrical to the shape marked on the bathtub.
ATTENTION: the templates are not symmetric!
Follow the same steps for the other side of the handle. Visually check that the marked
holes are correct by placing the handle over them.
6
1
3
2
5
1
4
2
3
4
RA
V
A
K
SILICONE
Put the handle in place and tighten the M8 screws and washers from the under side of
the bathtub. (Slight adjustments can be made by drilling the holes to a maximum of
10mm!).
Tighten the screws normally. Over-tightening of the screws can cause deformation of
the handle.
The manufacturer reserves the right to change the price, technical parameters or other facts without
a prior notice and shall bear no responsibility for the printing errors.