Service reports
142 / 153
V-12 - 02/2018 - PM/Stme - English - © RATIONAL
Service report
Error
Effects and action
Service 230
Error in the pan valve
drive
Automatic pan valve defect
Model 112: No restrictions in the right-hand
pan
Call customer service
Service 231
Error in the pan valve
drive (R)
Automatic pan valve defect
No restrictions in the left-hand pan
Call customer service
Service 240 + 242
Error in AutoLift-
system
Open left-hand cover and select AutoLift
again.
Do not close the cover manually during
AutoLift operation.
Service 241 + 243
Error in AutoLift
system (R)
Open right-hand cover and select AutoLift
again.
Do not close the cover manually during
AutoLift operation.