- 83 -
V08 en, SCC
+
Adjusting speed of blower motor steam (+/ -10%)
(After blower speed adjustment the original rpm is shown in the temp. display, the changed
rpm is shown in the time display)
Press time key, keep it pressed and adjust displayed rpm with timer dial
SE10 = MIN rpm; SE11 = Start rpm; SE12 = MAX rpm
NOTE: After changing speed of blower motor a flue gas analysis MUST be carried out in the
function test.
+
Adjusting speed of blower motor hot air top (+/ -10%)
(After blower speed adjustment the original rpm is shown in the temp. display, the changed
rpm is shown in the time display)
Press time key, keep it pressed and adjust displayed rpm with timer dial
SE13 = MIN rpm; SE14 = Start rpm; SE15 = MAX rpm
NOTE: After changing speed of blower motor a flue gas analysis MUST be carried out in the
function test.
+
Adjusting speed of blower motor hot air bottom (+/ -10%)
(After blower speed adjustment the original rpm is shown in the temp. display, the changed
rpm is shown in the time display)
Press time key, keep it pressed and adjust displayed rpm with timer dial
SE16 = MIN rpm; SE17 = Start rpm; SE18 = MAX rpm
NOTE: After changing speed of blower motor a flue gas analysis MUST be carried out in the
function test.
(De) activation of UltraVent
NOTE: Gas units: A flue gas analysis must be done after deactivation
0 = OFF, 1 = BUS, 2 = US version (from C2-00-05)
Setting. Press time key and select „0“ or „1“ with timer dial;
keep time key pressed and press Core key for 1 sec, release core key before
releasing time key,
Start Self test
(Duration: appr. 45min - 61-102, 60min - 201-202) with boiling point recog-
nition.
NOTE: Gas units: Gas blower speed will be adjusted
To change from 0 to I or vice versa set desired status with timer dial (0= self test disabled, I=
Self test enabled), keep time key pressed and press core key for 1 sec, release core key before
releasing time key,
Setting of chain account script Standard: nonE, Option: Apetito
Press time key and select „nonE“ or „APEt“ with timer dial;
keep time key pressed and press Core key for 1 sec, release core key before
releasing time key,
SoFt: Soft water ON / OFF
Reset error message:
After repair:
Press time key and select de-
sired setting with timer dial;
keep time key pressed and
press Core key for 1 sec, re-
lease core key before
releasing time key,
ACLn ON / OFF, automatic cleaning
ACLo ON / OFF, Automatic Cleaning => Logging on/off
CdSE auto / hour / off, Calc detection Setting => selected
way of scale detection (only when ACLn = ON
CdFC 0.5 - 2.0, Calc detection correction factor
CM_P - Basic settings - SE