6 | Electrical connection
80.06.243_iVario Pro L_XL_IM_V01_en-US
43 / 60
2. Screw in the 2 screws behind the cover of the socket.
>>
The electrical compartment is closed and protected against water and mois-
ture penetration.
6.6
Connected loads of different voltage types
Maximum connection voltage
n
Maximum permissible tolerance for the input voltage: - 10% to 10%
n
The device can be used with frequencies of 50 Hz and 60 Hz without tech-
nical modifications.
NOTE
The specified values for the conductor cross-section refer to a maximum
power cable length of 2 m [78 Inch]. Calculate the conductor cross-section
for the length and quality of the power cable used.
3 AC 440 V
Power kW
Power consump-
tion A
Fuse A
Conductor cross-sec-
tion AWG
iVario Pro L
25
33
45
8
iVario Pro XL
38
50
65
6
3 AC 208 V
Power kW
Power consump-
tion A
Fuse A
Conductor cross-sec-
tion AWG
iVario Pro L
23
64
80
4