10 | Gas connection for gas devices
80.06.083_iCombiPro-iCombiClassic_IM_en-US
79 / 96
6 half
size
6 full
size
10 half
size
10 full
size
20 half
size
20 full
size
Wobbe index (MJ/m³)
Ws
50.72
50.72
50.72
50.72
50.72
50.72
Max. consumption at
nominal heat load (at 15
°C, 1013 mbar)
48.58
ft³/h
104.64
ft³/h
82.21
ft³/h
149.48
ft³/h
156.96
ft³/h
298.96
ft³/h
Max. consumption at
nominal heat load (at 15
°C, 1013 mbar)
49500
BTU/hr
106500
BTU/hr
83500
BTU/hr
152000
BTU/hr
159500
BTU/hr
303500
BTU/hr
Propane gas 3P G31 USA
6 half
size
6 full
size
10 half
size
10 full
size
20 half
size
20 full
size
Required connection
flow pressure (mbar)
10-15
in/wc
10-15
in/wc
10-15
in/wc
10-15
in/wc
10-15
in/wc
10-15
in/wc
Wobbe index (MJ/m³)
Wi
74.75
74.75
74.75
74.75
74.75
74.75
Wobbe index (MJ/m³)
Ws
81.19
81.19
81.19
81.19
81.19
81.19
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
2.23 lb/
h
4.80 lb/
h
3.77 lb/
h
6.85 lb/
h
7.19 lb/
h
13.7 lb/
h
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
48500
BTU/hr
104000
BTU/hr
82000
BTU/hr
148500
BTU/hr
156000
BTU/hr
296500
BTU/hr