10 | Gas connection for gas devices
80.06.083_iCombiPro-iCombiClassic_IM_en-US
75 / 96
10
Gas connection for gas devices
This chapter only applies to gas devices.
DANGER
Fire due to incorrect gas connection
Risk of death due to fire caused by incorrect gas connection.
n
Observe the local regulations of the gas supply company.
n
Check the existing gas type and the dynamic connection pressure with the
values indicated on the device.
DANGER
Exceeding the permissible CO/CO
2
values
Risk of poisoning due to increased CO/CO
2
values caused by incorrect
burner settings.
n
Perform a flue gas analysis during initial commissioning.
n
Document the flue gas values.
n
It is recommended that the installation site be equipped with a CO gas
detector.
DANGER
Increased CO values due to incorrect gas type
Risk of poisoning due to connecting the wrong type of gas
n
Only connect the device to the gas type specified on the device's type
plate.
n
Check the existing gas type and the dynamic connection pressure with the
values indicated on the device.
n
It is recommended that the installation site be equipped with a CO gas
detector.
10.1 Gas connection regulations
NOTE
Exceeding the connection flow pressure
A connection flow pressure above 65 mbar [0.94 psi 26"w.c.] leads to a
malfunction of the device and damage of gas components.
n
For natural gas, maintain the maximum connection flow pressure of 30
mbar [0.44 psi].