- 15 -
V02 12/2013
- Units with left hinged doors:
There is a knock out for left hinged door
units in the stiffening plate, brake it out.
- At the rear side of stiffening plate there
are two holding angles (pos. 6). These
devices can be used for fixing the unit to
the wall.
- SCC/CM units manufactured up to
08/2011
Reinstall dome.
- SCC_WE/CM P units manufactured as
of 09/2011 dome is no longer required
- Fix cover for dome (pos. 7) to
stiffening plate
pic. 6
- Turn fixing lever of door ship units up
side down (lever must point to unit top
cover), by:
pic. 7
- Losing cap nut of fixing device (pic 7A)
- Take off fixing lever, turn it up side and
put it back on aganin
- Fasten cap nut
- Stick gasket vent pipe (pos. 2) over the
went pipe.
pic. 8
The Combi Duo kit contains different
gaskets, this is because the diameter of
the vent pipe differs in between the dif-
ferent models and sizes.
- Fix ventilation box (pos. 3) to stiffening
plate.
pic. 8
- Insert gasket exhaus pipe (pos. 4) into
ventilation box (pos 3).
pic. 8
- Reinstall door holding device. pic. B item I
- Remove door handle and install it
upside down, by:
- Removing plastic cover of the door
lock.
(Push cover in direction to inner side
of the door and take it out.)
- Loosen allen screw (5 mm) of the door
handle.
- Pull off door handle, turn it upside
down and install it again.
- Install plastic cover.
B) Top unit:
-
Remove cover frame of care pump con-
tainer, by loosing the screw on the front
cross part of the cover frame. pic 3 item A
- Undo lower part of the leg.
- Ship version unit's are equipped with fix-
ing plates.
- Stick these fixing plates (pos. X) over
the lower parts of the legs.
pic. 9
- Screw lower parts of the legs to the
upper part of the legs.
- Connect water supply and check for
tightness.
- Adjust unit legs to a length of 128,5 mm
- Put unit onto bottom unit.
- Level the unit with the height adjustable
legs (use spirit level).
pic. 9
- Secure the fixing plates of the legs with
the cap nuts and the studs of the stiffen-
ing plate.
- Stick exhaust pipe (pos. 5) into ventila-
tion box (pos. 3) and secure it by putting
the holding plate of the exhaust pipe
over the ventilation pipe of the upper
unit.
pic. 10
C) Mounting of air deflector
pic 11
- On the stiffening plate, below air filter of
the upper unit, there are two studs.
- Fasten the angle brackets (pos. 8) with
the nuts to the studs.
- Fasten air deflector (pos. 9) to the angle
brackets (pos. 8).
GB
Summary of Contents for 60.71.943
Page 2: ......
Page 4: ...V02 12 2013 4 A B 5 6 1 3 4 2 6 11 7 10 I 8 9 X 12...
Page 6: ...V02 12 2013 6 A B 5 6 1 3 4 2 6 11 7 10 I 8 9 X 12...
Page 8: ...V02 12 2013 8 1 2...
Page 9: ...9 V02 12 2013 150 mm 6 150 mm 6 150 mm 6 4 5 6 8 7 1 2 4 3 3 A A B 7...
Page 10: ...V02 12 2013 10 11 8 9 10 5 3 9...
Page 11: ...11 V02 12 2013 Notizen Note...
Page 16: ...V02 12 2013 16 6x1 1 GN 6x1 1 GN...
Page 17: ...17 V02 12 2013 6x1 1 GN 10x1 1 GN...
Page 18: ...V02 12 2013 18 6x2 1 GN 6x2 1 GN...