background image

Page 6

Appendix 2

Specifications:

Dimensions (H x W x L)

• Inverter: 

4.2” x 9.5 x 15.5

• Battery: 

8.3” x 6.6” x 10.2”

• Optional Relay Enclosure: 

2” x 9” x 9”

Electrical Ratings

• Inverter: 

Input

 

90-130vac, 60Hz  

ǀ

  AC Output 115vac, 60Hz  

ǀ

  DC Output 12vdc, 5A   

ǀ

  Simulated Sine Wave

• Battery: 

Output 12.5vdc  

ǀ

  82 Amp Hours

• Transfer Time: 

20ms (milliseconds)

Operating Temperature

• Inverter: 

32° F - 104° F  

ǀ

  UL94 Flame Retardant

• Battery: 

-10° F - 140° F (Recommended 68° F - 77° F)  ǀ  UL94 Flame Retardant

Protection: 

Short Circuit  

ǀ

  Overvoltage  

ǀ

  Overload  

ǀ

  Ground Fault

Regulatory Approval

• 

CSA 22.2 NO 107.1 (Power Conversion Equipment)

• 

UL 458

Error Code

Condition

Action

E01

Low battery voltage shutdown

• Check battery status and recharge if necessary

• Check for proper DC cable size

• Check for loose connections and tighten if necessary

E02

High battery voltage shutdown

• Check for external charging sources and disconnect   

  if necessary

E03

AC output overload shutdown

• Reduce the loads connected to the AC outlet

E04

Over temperature shutdown

• Reduce the loads connected to the AC outlet

• Check that the ventilation grille is not blocked

• Check ambient temperature and move unit if    

  necessary

E05

Low battery voltage detected

• Check battery status and recharge if necessary

• Check for proper DC cable sizing

• Check for loose connections and tighten if necessary

E06

AC output overload warning

• Reduce the load connected to the AC outlet

E07

Over temperature warning

• Check that the ventilation grille is not blocked

E11

Over temperature on AC transfer relay

• Check that the ventilation grille is not blocked

E12

Battery bad or DC load connected to battery • Check battery, battery should rise above 10vdc after 

  15 minutes

Appendix 3

Error Code:

Reviews: