Page 6
Appendix 2
Specifications:
Dimensions (H x W x L)
• Inverter:
4.2” x 9.5 x 15.5
• Battery:
8.3” x 6.6” x 10.2”
• Optional Relay Enclosure:
2” x 9” x 9”
Electrical Ratings
• Inverter:
Input
90-130vac, 60Hz
ǀ
AC Output 115vac, 60Hz
ǀ
DC Output 12vdc, 5A
ǀ
Simulated Sine Wave
• Battery:
Output 12.5vdc
ǀ
82 Amp Hours
• Transfer Time:
20ms (milliseconds)
Operating Temperature
• Inverter:
32° F - 104° F
ǀ
UL94 Flame Retardant
• Battery:
-10° F - 140° F (Recommended 68° F - 77° F) ǀ UL94 Flame Retardant
Protection:
Short Circuit
ǀ
Overvoltage
ǀ
Overload
ǀ
Ground Fault
Regulatory Approval
•
CSA 22.2 NO 107.1 (Power Conversion Equipment)
•
UL 458
Error Code
Condition
Action
E01
Low battery voltage shutdown
• Check battery status and recharge if necessary
• Check for proper DC cable size
• Check for loose connections and tighten if necessary
E02
High battery voltage shutdown
• Check for external charging sources and disconnect
if necessary
E03
AC output overload shutdown
• Reduce the loads connected to the AC outlet
E04
Over temperature shutdown
• Reduce the loads connected to the AC outlet
• Check that the ventilation grille is not blocked
• Check ambient temperature and move unit if
necessary
E05
Low battery voltage detected
• Check battery status and recharge if necessary
• Check for proper DC cable sizing
• Check for loose connections and tighten if necessary
E06
AC output overload warning
• Reduce the load connected to the AC outlet
E07
Over temperature warning
• Check that the ventilation grille is not blocked
E11
Over temperature on AC transfer relay
• Check that the ventilation grille is not blocked
E12
Battery bad or DC load connected to battery • Check battery, battery should rise above 10vdc after
15 minutes
Appendix 3
Error Code: