VoIP & Wi-Fi VoIP:

See additional manual.

GSM Cellular:

1. 

Open Access Panel 1 (see Figure 1) using torx bit to remove security screws.

2. 

Remove the cover of the NEMA 4 enclosure. 

3. 

Locate the Cellular Module inside the enclosure.

  

4. 

When the “PWR”, “RDY”, and “NW” lights on the front of the unit are illuminated, unit is ready. 

5. 

Verify SmartPhone is plugged into the FXS port on Cellular Module.

Note:

 If the SIM card is not provided to RATH® at time of purchase, an active SIM Card will need to be installed 

into SIM Card slot.

CDMA Cellular:

1. 

Open Access Panel 1 (see Figure 1) using security torx bit to remove security screws.

2. 

Remove the cover of the NEMA 4 enclosure. 

3. 

Locate the Cellular Module inside the enclosure. 

4. 

When “Power”, “Signal Strength”, and “Service Indicator” lights are illuminated solid, unit is ready.

 

5. 

Verify SmartPhone is plugged into the phone port on Cellular Module.

2-Way Radio:

The 2-Way Radio phone can both transmit and receive voice communications. Our 2-Way Radios are fixed  in 

the Tower and must be programmed to the specifics of the 2-Way System in use within the facility or campus. The 

2-Way Radio is programmed at the factory using customer provided information (frequency, squelch code, 

and narrow or wide bandwidth). The antenna is installed and tuned at the factory. Towers using 2-Way Radio 

are not ADA compliant (the button must be pushed and held to talk and let go to listen).

Note:

 Phones using 2-Way Radios are not programmable. Sections in this manual on 

Programming the Phone

 

do not apply.

Adjusting the Volume for 2-Way Radio:

1. 

If the volume of the Tower needs to be adjusted, remove Access Panel 1 located on the back of Tower.

 

2. 

Open the NEMA 4 box to access the radio. Turn the radio volume control up or down to adjust. 

3. 

Close the NEMA 4 box and reattach Access Panel 1.

900 MHz:  

Each Tower includes (2) 900 MHz units, (1) Remote Station, and (1) Base Station. The Remote Station  is  

already installed in the Tower.

 

1.

 Locate the 900 MHz unit with Base Station labeled on the bottom.

2. 

Screw the black antenna into the back of 900 MHz Base Station.

3. 

Plug a dedicated analog phone line or analog extension off of a PBX system into the port labeled “Line”.

4.

 Connect Power Cable included with unit into dc input on Base Station and a 120v outlet.

5.

 Test units by taking an analog phone and plugging it into the “Line” Port on Remote Station installed in     

    the Tower. There should be a dial tone and you should be able to place a call out.

6. 

Verify SmartPhone is plugged into “Tel” Port on Remote Station. Phone is now ready for programming.

Note:

 If installing multiple 900 MHz units, please put a minimum of 3 feet between each Base Station. Connect 

one unit at a time, test, and then continue adding one unit and testing until all units are ready and functional.

Page 7

Summary of Contents for 2100-TS9

Page 1: ...RP8500080 Ver 4 10 17 36 Emergency Call Station Installation Operations Manual Emergency Tower Phone 2100 TSL Landline Solar Tower 2100 TSC Cellular Solar Tower 2100 TS9 900 MHz Solar Tower 2100 TST 2...

Page 2: ...t with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business The RATH Team N5...

Page 3: ...rage Be careful of finished surfaces during transport and installation to avoid damaging the finish Installation and maintenance should only be performed by qualified electricians It is recommended th...

Page 4: ...crete pad protecting the Tower surface 2 Assemble solar strobe tube to the top of the Tower using the four bolts flat washers and lock washers The mounting hardware is in a bag attached to the solar t...

Page 5: ...to the bracket 7 Solar panel position is preset to winter months due to lower amounts of sunlight We recommend you keep it at the factory preset angle Secure solar panel bracket to solar panel in four...

Page 6: ...n Saver in the NEMA 4 enclosure see drawing below 4 Using a voltmeter check each set of terminals for Solar Battery and Load The voltage should measure between 12 6 and 13 8 volts on each set If volta...

Page 7: ...ers using 2 Way Radio are not ADA compliant the button must be pushed and held to talk and let go to listen Note Phones using 2 Way Radios are not programmable Sections in this manual on Programming t...

Page 8: ...Press 8 Enter 3 digit number in minutes Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number of the Tower B Afte...

Page 9: ...one below When the party you called hangs up does the strobe stop If you have answered YES to all questions you have successfully installed and tested the phone If you answer NO to any question procee...

Page 10: ...the solar terminals Using a voltmeter measure the voltage across the two terminals It should read approximately 20 volts dc on a sunny day If voltage is low or 0 the panel may be damaged Disconnect th...

Page 11: ...Page 11 Wiring Optional...

Reviews: