background image

Items Needed for Installation

Installation

1.

 Remove 12 security screws from unit 

2.

 Remove top cap from unit

3.

 Pull front assembly away from back unit

4.

 Disconnect the gray Wago connector (see diagram on page 

8

)

5.

 If wall mount, mount to wall 

6.

 If pole mount, attach unit to pole using Pole Mounting Bracket (RP7700098A)

7.

 Connect the electrical conduit of the 110vac power supply to the Call Station and run  necessary wires

8.

 Connect 110vac wiring to the Call Station power cable (see diagram on page 

8

)

9.

 Turn on 110vac power to the Call Station

Once the electrical is “live”, the phone needs to be programmed and tested. Reconnect the Wago connectors  that 

attach the front plate to the NEMA 4 box. If the phone will be programmed remotely, secure the front  assembly to the 

back panel and reinstall the 12 screws to the sides of the unit. If the  phone will be programmed on-site, proceed to 

the directions for “On-Site Programming”.  

Communication

Page 4

Item

Description

Wall Mounting Hardware

If Mounting to Wall

Pole Mount Bracket (Part # RP7700098A)

If Mounting to Pole

#1 Phillips Screwdriver
Voltage Meter
Security Torx Bit

Provided by RATH

®

Adjustable Wrench
120v Power Source
Analog Phone Line

If Using Landline

Phone Cable

If Using Landline

Landline:

To connect your analog phone line to the Emergency Call Station:

1.

 Remove front Stainless Steel plate using the security torx bit to remove the 6 security screws.

2.

 Locate the gray phone cable coming out of the NEMA 4 box.

3.

 Connect the incoming phone line by connecting the tip and ring of the phone line to red and green of 

    provided gray line cord.

Summary of Contents for 2100-CPC

Page 1: ...com RP8500CP Ver 6 04 21 36 Emergency Call Station Installation Operations Manual 36 Emergency Call Station 2100 CPL Landline 120v Call Station 2100 CPC Cellular 120v Call Station 2100 CPV VoIP 120v C...

Page 2: ...to remotely assist with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business...

Page 3: ...during installation and with maintenance Keep all the components secure and protected during storage Be careful of finished surfaces during transport and installation to avoid damaging the finish Inst...

Page 4: ...the phone will be programmed remotely secure the front assembly to the back panel and reinstall the 12 screws to the sides of the unit If the phone will be programmed on site proceed to the directions...

Page 5: ...ectly and has an active 4G data voice plan 4 A signal strength test is recommended Check the signal strength by using the built in network signal strength scanner To use the scanner function turn on S...

Page 6: ...erval is 1 minute A Press 8 Enter 3 digit number in minutes Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number...

Page 7: ...roceed to the Troubleshooting Section Push the emergency button on the front of the Call Station Yes No RATH recommends the Call Station be tested on a regular basis to ensure proper operation Adjusti...

Page 8: ...m is not providing a disconnect signal Contact the appropriate party to make sure the disconnect signal is provided When the called party hangs up busy signal is heard through speaker Phone company or...

Page 9: ...rd Play Pause Stop Constant Strobe to 900 MHz Radio or Cellular y r e t t a B Communication Source LED for Panel FRONT COVER Note If using landline phone cable will just run out of the bottom of the N...