background image

Landline:

To connect your analog phone line to the Emergency Call Station:

1.

 Remove front Stainless Steel plate using the security torx bit to remove the 6 security screws.

2.

 Locate the gray phone cable coming out of the NEMA 4 box.

3.

 Connect the incoming phone line by connecting the tip and ring of the phone line to red and green of provided 

    gray line cord.

Page 5

GSM Cellular:

1.

 Remove security screws, top cap, and pull front of the Call Station enclosure down.

2.

 Remove the cover of the NEMA 4 enclosure mounted to the front of the Call Station enclosure. 

3.

 Locate the Cellular Module inside the enclosure.  

4.

 When the “PWR”, “RDY”, and “NW” lights on the front are illuminated, unit is ready. 

5.

 Verify SmartPhone is plugged into the FXS port on Cellular Module.

Note:

 If the SIM card is not provided to RATH® at time of purchase, an active SIM Card will need to be installed into 

SIM Card slot. When installing SIM Card, disconnect power from cellular unit, install SIM Card in SIM Card slot, 
then reapply power.

CDMA Cellular:

1.

 Remove security screws, top cap, and pull front of the Call Station enclosure down.

2.

 Remove the cover of the NEMA 4 enclosure mounted to the front of the Call Station enclosure. 

3.

 Locate the Cellular Module inside the enclosure. 

4.

 When “Power”, “Signal Strength”, and “Service Indicator” lights are illuminated solid, unit is ready.    

5.

 Verify SmartPhone is plugged into the phone port on Cellular Module.

2-Way Radio:

The 2-Way Radio phone can both transmit and receive voice communications. Our 2-Way Radios are fixed  in the

 

Call Station and must be programmed to the specifics of the 2-Way System in use within the facility or campus.

 

The 2-Way Radio is programmed at the factory using customer provided information (frequency, squelch code, 

and narrow or wide bandwidth). The antenna is installed and tuned at the factory. Call Stations using 2-Way Radio 

are not ADA compliant (the button must be pushed and held to talk and let go to listen).

Note: 

Phones using 2-Way Radios are not programmable. Sections in this manual on 

Programming the Phone

 do 

not apply.

Adjusting the Volume for 2-Way Radio:

1.

 If the volume of the Call Station needs to be adjusted, remove security screws, top cap, and pull front  of 

    the Call Station enclosure down.

2.

 Open the NEMA 4 box to access the radio. Turn the radio volume control up or down to adjust. 

3.

 Close the NEMA 4 box.

900 MHz:

Each Call Station includes (2) 900 MHz units, (1) Remote Station, and (1) Base Station. The Remote Station  is 

already installed in the Call Station.

1.

 Locate the 900 MHz unit with Base Station labeled on the bottom.

2. 

Screw black antenna into back of 900 MHz Base Station.

3. 

Plug dedicated analog phone line or analog extension off of a PBX system into the port labeled “Line”.

4.

 Connect Power Cable included with unit into dc input on Base Station and a 120v outlet.

5.

 Test units by taking an analog phone and plugging it into the “Line” Port on Remote Station installed in     

    the Call Station. There should be a dial tone and you should be able to place a call out.

6. 

Verify SmartPhone is plugged into “Tel” Port on Remote Station. Phone is now ready for programming.

Note:

 If installing multiple 900 MHz units, please put a minimum of 3 feet between each Base Station. 

Connect one unit at a time, test, and then continue adding one unit and testing until all units are ready and functional.

Summary of Contents for 2100-CD9

Page 1: ...2Dawn Call Station 2100 CD9 900 MHz Dusk2Dawn Call Station 2100 CDT 2 Way Radio Dusk2Dawn Call Station 2100 CDV VoIP Dusk2Dawn Call Station 2100 CDW Wi Fi VoIP Dusk2Dawn Call Station N56W24720 N Corpo...

Page 2: ...o remotely assist with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business...

Page 3: ...Keep all the components secure and protected during storage Be careful of finished surfaces during transport and installation to avoid damaging the finish Installation and maintenance should only be...

Page 4: ...med Warning Electrical Connection Should Be Performed by a Qualified Electrician 480 Volt AC Supplies Connect H1 and H4 on the transformer to the hot and neutral of the 480 volt supply Connect H2 and...

Page 5: ...to the specifics of the 2 Way System in use within the facility or campus The 2 Way Radio is programmed at the factory using customer provided information frequency squelch code and narrow or wide ba...

Page 6: ...rval is 1 minute A Press 8 Enter 3 digit number in minutes Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number...

Page 7: ...to the Troubleshooting Section Push the emergency button on the front of the Call Station Yes No RATH recommends the Call Station be tested on a regular basis to ensure proper operation Adjusting the...

Page 8: ...t providing a disconnect signal Contact the appropriate party to make sure the disconnect signal is provided When the called party hangs up busy signal is heard through speaker Phone company or phone...

Page 9: ...robe Wago Connector to front plate 1 4 5 7 8 0 9 6 3 2 Enter Record Play Pause Stop Constant Strobe 120vac Charging Finishing Ready Dusk2Dawn Charging Station Ground Positive Negative Photocell y r e...

Reviews: