background image

EN

11

If the blade is no more able to cut (even after repeating

the sharpening operation several times) it is necessary to
replace it. To carry out this operation, use butterfly wrench

“1”  (shown  in  picture  8).

To replace the blade, proceed as follows:

1) Use  some  protective  gloves  in  compliance  with

Italian Legislative Decree 81/08.

2) Remove the  two adjusting  knobs  “A” and  “D”  of

the right and left protection covers “C” and “F” by

removing  the  two  relative  washers  “B”  and  “E”

(see picture 9).

3) Unscrew screws “M” and remove counterblade “L”,

then unscrew nut “G” by using a butterfly wrench

“1” and remove blade “H” (see picture 10).

4) Replace  the  worn  blade  with  the  new  one  “2”,

being careful to center the blade on the gear, in

the correct position; we remind you to assemble
it so that the side with the writing Rasor can be

seen by the operator.

6)   Assemble all the components again and carry out

the sharpening.

 13.  BLADE REPLACEMENT

9

D

8

1

10

E

F

A

B

C

H

1

G

2

 14.  SLIDING FOOT REGULATION

For a good  cut, the circular blade must  always brush against

the slot end of the sliding foot (without touching it!).
When the blade wears, its diameter is reduced and therefore

the sliding foot must be brought again near the blade. In order

to reach this goal:

1)

Unscrew screw “A” under the base and bring the sliding

foot near the blade (see pictures 11 and 12).

2)

Tighten  screw  “A”  again  and  carry  out  some  cut  tests

(see picture 12).

11

12

A

L

M

Summary of Contents for DD120RC

Page 1: ...USE MANUAL English CUTTING UNIT MOD DD120RC ED 1 09 14 SERIAL NUMBER...

Page 2: ...y Luigi Spinelli For more than sixty years it has been producing automatic cutting systems cutting units for textile applications and electric and pneumatic cutters Initially considered as a point of...

Page 3: ...the feed cable of the machine It must never be replaced by the user If necessary contact professionally qualified staff KEEP THE WORKING AREA ALWAYS IN ORDER The workplace must always be kept in orde...

Page 4: ...t work in case of rain In case of damage or malfunction cutting unit DD120RC must not be used until the Customer Care Technical Service has repaired them The original configuration of the cutting unit...

Page 5: ...ll even if the machine is resold Always refer to the serial number written on the plate itself when contacting the manufacturer Several safety warnings are printed on a card which is applied to the cu...

Page 6: ...ers A sharpener assembled on the cutting unit head allows whetting the blade at any moment without disassembling it After carrying out this operation it is possible to start cutting again A high power...

Page 7: ...ar blades This equipment must not work in areas prone to explosions in presence of fine dust or corrosive gases on wet or damp materials to cut plastic metal and wooden materials It is forbidden to us...

Page 8: ...rking or while the electric plug is connected Always pay attention to the electric cable position to prevent it from being cut or damaged by the blade It is allowed to assemble cutting unit DD120RC on...

Page 9: ...rminal board The minimum section of the connecting cables must be determined by the operator in charge of the installation We recommend using safety cables and sockets IMQ approved Check the connectio...

Page 10: ...cutting unit on level squares or angles by using the two threaded holes A for 5MA screws located in the blade holder support see picture 4 NOTE The cutting unit can be installed in any position angle...

Page 11: ...ure 10 4 Replace the worn blade with the new one 2 being careful to center the blade on the gear in the correct position we remind you to assemble it so that the side with the writing Rasor can be see...

Page 12: ...26300 BLADE FIXING RING NUT GMT12DD COMPLETE MOTOR SERIES DD120 3 ph 380 V 50 Hz GRT27 FLAME RETARDANT FEEDING CABLE SW121100 STEEL PIN SW1274DDR C RIGHT BASE WITH BEVEL DD120R GRT1213DD COMPLETE ROTO...

Page 13: ...26 GRT12M28 GRT12DD24 SW121600 GRT1213DD GRT12M27 GRT12M21 GRT8615 GRT12M17 GRT12M18 GRT12M19 GRT8616 GRT12M22 GRT27 SW109200 SW1286CPL SW108800 SW109300 SW128600 SW108700 SW109100 T 107500 SW109000 S...

Page 14: ...ng expenses The warranty does not include failure caused by wrong use or assembly failure caused by external agents failure caused by lack of maintenance or neglicence blades and parts subject to wear...

Page 15: ...ds We declare that the above mentioned goods comply with the standards in force concerning safety and hygiene at work that can be applied to the material itself according to the Italian legislative de...

Page 16: ...Authorized dealer Stamp...

Reviews: